dormakaba Universal Patch Fittings PT60/61
Installation Instructions
1  Technical specifications
1.1

Overview

These instructions are for installation of the Universal
PT60/61 Connector for Overpanel and Sidelite with/
without Fin Patch Fittings for the following mounting
and style versions:
1. Glass mounting
1.1.1

General information

dormakaba requires use of tempered monolithic
glass.
dormakaba glass hardware is not suitable for harsh
environment; for example, applications where
chemicals (e.g. chlorine) are used such as indoor
swimming pools, saunas, or salt-water pools.
Do not swing doors with excessive force. Install
limiting stop to prevent door from opening too far.
1.1.2

Intended use

For pivoting doors in indoor or covered areas only.
For manual slowly opening and closing only.
1.1.3

Glass requirements/fittings/mounting

The substructure/wall must be able to bear
permanent loads, and be level (max. tolerance:
1/16" [2] per 39" [1m]).
Fasteners must be sufficiently dimensioned for the
substructure/wall and weight of the door.
When adjusting glass elements, always stick to the
required clearance for the respective hardware.
Adjust clearance so glass does not come in contact
with any hard surfaces such as glass, metal or
concrete.
Do not use excessive force when installing the glass
(avoid over tightening screws.)

Requirements for glass panel

1.1.4
dormakaba requires use of fully tempered glass,
which complies with ASTM C 1036 and ASTM C
1048. Secondary heat soaking processes are
optional but not required.
Clamping area must be flat and uncoated (no
self-cleaning coating!)
Never use glass with conchoidal fractures and/or
damaged edges.

Safety instructions

1.1.5
Installation requires two people.
Always wear protective clothing.
Universal Patch Fittings
1.1.6
1.1.7
1.1.8
Disposal in accordance with local, state and national
regulations.
833005
Only properly qualified and specially trained staff
are authorized to mount dormakaba glass
hardware.
Due to crushing hazards and possible injury caused
by breakage of glass during mounting,
corresponding protective clothing (especially gloves
and protective goggles) is required.
Never clamp metal fitting hardware directly to
glass surface.

Symbols used - Safety/Installation

CAUTION
Mounting components must meet the
requirements of substructure/wall and door
weight. Please read the technical information
for fittings.
WARNING
Risk of breaking glass. When installing the
door, support the door panel with a block of
wood or similar object.
CLOSING EDGE OF DOOR

Maintenance, care, repair

Immediately replace damaged parts.
Always use original dormakaba parts.
Clean clamping area with alcohol-based standard
commercial cleaning agent before mounting the
glass hardware.
Use a damp cloth for occasional cleaning.
Always use silicone - and oil-free cleaners (e.g.
acetone).
Check glass hardware at regular intervals for
proper positioning, smooth operation and correct
adjustment.
High traffic door systems require inspection by
properly qualified staff (specialized companies or
installation firms.)
Function of fittings is recommended to be
inspected every 500,000 movements by a specialist.

Disposal

Technical specifications

07-2019