Installation and operation
If the passcode protection is disabled (the parameter PS is oFF), the passcode is not
requested.
If the
acters appear on the display: I- - - - . This means that the upper end of the menu has
been reached.
If the
characters appear on the display: - - - -I. This means that the lower end of the menu has
been reached.
Briefly push the
cates the actual parameter value. The factory settings are shown in Fig. 5.3 and Table 2.
The value can be changed using buttons
button, you return to the parameter list.
Potential errors and troubleshooting measures are listed in Table 5.2.
Table 5.2 Error display
Lo
Hi
None
akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover· Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de
button is pressed while the parameter PS is being displayed, the following char-
button is pressed while the parameter Sqrt is being displayed, the following
button (< 1 s) to change the selected parameter. The display indi-
Display
Possible cause of error
Input current lower than 3.8
mA
Input current higher than
22.5 mA
No input signal
Reverse polarity on input
and
. After confirming by pressing the
Remedy
Check input signal
Check input signal
Check input signal
Check polarity
9