Akytec PR102 MINI-PLC 40 I/O Краткое руководство по эксплуатации

Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Реле Akytec PR102 MINI-PLC 40 I/O. Akytec PR102 MINI-PLC 40 I/O 2 страницы. Programmable relay

Akytec PR102 MINI-PLC 40 I/O Краткое руководство по эксплуатации
WARNING
Switch off the supply voltage before working on the relay or
connecting or disconnecting it with other devices or PC. Switch the
supply voltage on only after all works has been completed.
CAUTION
The program runs after transferring it to the relay. It is recommended
to transfer the program before wiring the relay. Otherwise ensure that
all peripheral devices are disconnected from relay outputs before
transferring the program.
1. Specifications
Table 1 General specification
Power supply
Power consumption, max.
Galvanic isolation
Reverse polarity protection
Digital
Inputs
Analog
Digital
Outputs
Analog
Network interface
Protocol
Mode
Baud rate
Galvanic isolation
Extension modules
Real-time clock accuracy
Backup battery
Dimensions (with terminal blocks)
Mounting
Weight
Table 2 Digital inputs
HIGH level
LOW level
Pulse length, min.
Response time, max.
Pulse frequency, max.
Galvanic isolation
Table 3 Analog inputs
ADC resolution
Sampling time, max.
Galvanic isolation
Analog mode 1 (Linear input)
Input signal
Input resistance for 0-10 V input
Basic error
Temperature influence
Analog mode 2 (Temperature sensors)
Input signal
Least significant bit value
PTC thermistors
Basic error
NTC thermistors
Temperature influence
Nominal input voltage
HIGH/LOW threshold
(adjustable in ALP)
LOW/HIGH threshold
(adjustable in ALP)
Pulse length, min.
Signal frequency, max.
Table 4 Sensors (analog mode 2)
Sensor
Pt 500 (α = 0.00385 °С
−1
)
500P (α = 0.00391 °С
−1
)
Cu 500 (α = 0.00426 °С
−1
)
500M (α = 0.00428 °С
−1
)
Ni500 (α = 0.00617 °С
−1
)
Cu 1000 (α = 0.00426 °С
−1
)
1000M (α = 0.00428 °С
−1
)
Pt 1000 (α = 0.00385 °С
−1
)
1000P (α = 0.00391 °С
−1
)
Ni 1000 (α = 0.00617 °С
−1
)
Thermistors / NTC
B57861S series, 2 kΩ, B
= 3560K
25/100
PR102.24.2.2_3-EN-80145-1.4
© All rights reserved. Subject to technical changes and misprints.
24 (9...30) V DC
8 W
no
yes
16
8
14
2
2 × RS485
Modbus-RTU, Modbus-ASCII
Master/Slave
9.6...115.2 kbit/s
1500 V / 1 s
up to 2 PRM
± 3 s / day
CR2032
123 × 108 × 58 mm
DIN-rail (35 mm)
approx. 250 g
8.5...30 V / 2...5 mA
-3...+5 V / 0...15 mA
5 ms
30 ms
200 Hz
no
12 bit
1 ms
no
0-10 V, 4-20 mA, 0-300 kΩ
10 kΩ
±0.5 %
±0.5 % / 10 °C
see Tab. 4
1 °C
±1.5 %
±1.0 %
±0.5 % / 10 °C
Digital mode
24 V DC
2.5...10 V
3...10.5 V
5 s
100 Hz
Measurement range
RTD
–200...+850 °С
–200...+850 °С
–50...+200 °С
–180...+200 °С
–60...+180 °С
–50...+200 °С
–180...+200 °С
–200...+850 °С
–200...+850 °С
–60...+180 °С
–55...+100 °С
PR102.24.2.2
Programmable relay
B57861S series, 3 kΩ, B
B57861S series, 5 kΩ, B
B57861S series, 10 kΩ, B
B57861S series, 30 kΩ, B
B57861S series, 50 kΩ, B
NTC 3435, 10 kΩ
NTC 3977, 10 kΩ
KTY82-110
KTY82-120
KTY82-121
KTY82-122
KTY82-150
KTY82-151
Table 5 Digital outputs
Type
Switching capacity
Load current at 5 V DC, min.
Service life, electrical
Galvanic isolation
between outputs
against other circuits
Table 6 Analog outputs
Output signal
External voltage supply
Basic error, max.
Temperature influence
DAC resolution
R
Load
resistance
R
Galvanic isolation
2. Operating conditions
The device is designed for natural convection cooling.
The following environmental conditions must be observed:
• clean, dry and controlled environment, low dust level
• closed non-hazardous areas, free of corrosive or flammable gases
Table 7 Operating conditions
Condition
Operating temperature
Relative humidity
Attitude
IP code
EMC immunity
EMC emission
3. Installation
Installation:
1. Place the device on a DIN rail as shown in Fig. 2.
2. Press the device firmly against the DIN rail in the direction of arrow 2
until the latch locks.
akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany
Sensor
= 3988K
25/100
= 3988K
25/100
= 3988K
25/100
= 3964K
25/100
= 3760K
25/100
Thermistors / PTC
5 A, 250 V AC (resistive load)
AC
DC
200,000 switching cycles
AC
100,000 switching cycles
DC
(4-20 mA), max.
I
(0-10 V), min.
U
Permissible range
-40...+55 °C
up to 80 % (at +25 °C, non-condencing)
up to 2000 m above sea level
conforms to IEC 61000-6-2
conforms to IEC 61000-6-4
Fig. 1 Dimensions
Fig. 2
Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de
Measurement range
–55...+145 °С
–35...+145 °С
–35...+155 °С
–20...+155 °С
–10...+155 °С
–40...+105 °С
–40...+125 °С
–55...+150 °С
relay (NO)
3 A, 30 V DC
10 mA
individual
1780 V
2300 V
4-20 mA, 0-10 V
15...30 V
±0.5%
±0.5% / 10°C
12 bit
300 Ω
1 kΩ
510 V / 1 s, individual
IP20