Battery Tender Plus 12V1.25A Информация о продукте - Страница 4
Просмотреть онлайн или скачать pdf Информация о продукте для Зарядное устройство Battery Tender Plus 12V1.25A. Battery Tender Plus 12V1.25A 5 страниц. 12/6 volt, 1.25 amp
Stage 1) Bulk Charge: Red Light On, Green Light Off, Constant Current = 1.25 Amps,
Transition to Stage 2, Absorption Charge when battery voltage reaches 7.25 VDC.
Stage 2) Absorption Charge: Red Light On, Absorption Voltage = 7.25 VDC Transition
to Float Charge when battery charging current drops below 0.1 amp or until 6 to 8 hours
have elapses.
Stage 3) There is no Equalization Charge, Go directly to stage 4.
Stage 4) Float Charge: Red Light Off, Green Light On. Float Voltage = 6.6 VDC. If
an external load is applied to the battery while the charger is in stage 4, Float Charge, and
if the battery voltage drops below a range between 6.0 to 6.25 VDC, then the charge
cycle restarts.
Battery
Terminal
Voltage
(VOLTS)
10.0
9.5
9.0
8.5
1.25 Amps
8.0
Bulk Charge
7.5
7.0
6.5
6.0
5.5
5.0
0
1
2
3
Figure 1 Charging Graph: Battery Tender
______________________________________________________________________________________
Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL 32724
Phone 386-736-7900 FAX 386-736-0379
Battery Tender
R
Battery Tender
6 Vdc 1.25 Adc Output
Typical Charging Curve
Approximately
80% Recharged
Absorption
(6 to 8 Hours Max)
7.25 Volts
4
5
6
7
Charging Time (Hours)
www.batterytender.com
BATTERY TENDER PLUS
PRODUCT INFORMATION
®
Plus 6V1.25A:
Plus Battery Charger
100%
Recharged
Float / Maintenance
6.6 Volts
0.1 Amp
8
9
10
11
12
®
Plus 6V1.25A
Battery
Charging
Current
(AMPS)
2.0
1.8
1.6
1.4
1.25
1.2
1.0
0.8
0.6
0.4
0.2
0.1
0
13
14
15
16
4 of 5
Page
Revised April 4, 2002