beyond the point of being properly recharged or reconditioned/desulfated.
Dispose of the battery.
4. If each cell floats three (3) or more balls (or 1250 on gauge-type), your
battery can be desulfated/reconditioned.
5. Always rinse the tester with fresh water after every use. Failure to do so
will cause false readings.
Testing a Sealed, AGM or GEL Lead Acid Battery
These batteries have no filler caps or manifold-type covers. Because you
cannot gain access to the interior of your battery you cannot test it with a
hydrometer.
USE A DIGITAL VOLTMETER ONLY:
1. Recharge the battery with the BatteryMINDer to ensure it is as completely
charged as possible, before you determine its condition. Allow battery to
"rest" overnight for a minimum of 12 hours before testing with a digital
voltmeter only. Failure to test a "rested" battery will cause false readings.
Be certain to read and understand all safety related instructions (pages 2
to 7) before proceeding further.
2. Measure battery's voltage, without any load attached. If the voltage is less
12.4 volts
than
too heavily sulfated to be fully recoverable. If voltage is
higher full recovery can be expected, given sufficient time (average 1-2
weeks for batteries that are heavily sulfated).
3. Connect the BatteryMINDer to the battery. Charge battery to its maximum
level. Allow battery to rest for a minimum of 8 hours before retesting. If
improvement is seen, continue until battery voltage reaches full capacity
level or no further increase is seen. Refer to Open Circuit No Load
Voltage table.
OCV - "Rested" Voltage
12V
12.9 - 13.1
12.6 - 12.9
12.4 - 12.6
12.2 - 12.4
12.0 - 12.2
<11.0 = shorted
Note:
All OPTIMA brand starter/deep cycle batteries have a fully charged
"resting" voltage of 13.1 (OCV). Increase above values accordingly.
Rev. A2-010516
®
/
24.8 volts
(Typically 50% of charge) the battery may be
OCV=Open Circuit No Load Voltage
<22.0 = shorted
24V
25.8 - 26.2
25.2 - 25.8
24.8 - 25.2
24.4 - 24.8
24.0 - 24.4
Page 7
Models 128CEC1 & 244CEC1
12.4V
/
Full Capacity
Percentage
100%
75%
50%
25%
0%
P/N VDC128/244-CEC1-QSS
24.8V