8 -FIRST SWITCH-ON AND USE
When switching on the pneumatic fuel conveyor system for the fi rst time, make sure that the product
English
is perfectly airtight, with particular reference to the pipe unions and to the bucket fastening fl ange.
After a few operating cycles, check the residues that have gathered up on the bucket bottom, to
determine how frequently it will have to be emptied.
9 -MAINTENANCE AND END OF LIFE
Periodically check the amount of dusts that has gathered up on the bucket bottom, and never let the
level exceed ¾ of the total bucket capacity.
To remove the bucket, release the two handle hooks that keep it in contact with the separator, then
unhook it.
Emptying the bucket
After disposing of the content and before reinstalling the bucket, check that no residues have remai-
ned on the gasket and under the coupling fl ange, as they would compromise the sealing between
separator and bucket; remove any residues, then properly hook the bucket.
The dusts that gather up in the bucket must be disposed of properly and in compliance with the
local regulations in force.
9
23/05/2022 Rev:1.0.0