DOTECH FX3DH-A1 Руководство - Страница 3
Просмотреть онлайн или скачать pdf Руководство для Контроллер DOTECH FX3DH-A1. DOTECH FX3DH-A1 4 страницы. Digital temp. & humidity controller
Setting 2 Group
Display Current Temp.
Push for
5 sec.
Push for
3 sec.
IN
H
Setting 1 Group Table
NO
DESCRIPTION
100
Select Control Type
101
Control Deviation Value
102
Select Deviation Value
Output #1
104
Output #2
ON Delay Time ( ※ 1)
105
Output #3
Minimum OFF Time ( ※ 2)
Output #4
106
Minimum ON Time ( ※ 3)
107
Output at Sensor Error ( ※ 4)
Common
&
108
Alarm Deviation Value
Individual
setup
109
Alarm Option
110
High limit by user setup
111
Low limit by user setup
112
Manual Output Mode Output ( ※ 5)
113
Manual Output Value Output ( ※ 6)
※
1) ON delay time : It outputs after setting delay time in spite of output condition. During ON delay time, output lamp is turned on with output after flickering in fast cycle
2) Min OFF Time : It lets output not occur within min. OFF time after it is turned off. During min. OFF time, output lamp is turned on with output after it flickers every 1 second intervals
※
※
3) Min ON Time : It is for avoiding frequent ON/OFF of control output and maintains ON condition in spite of OFF condition during Min ON Time after being turned on. (In case of sensor error, OFF at once)
※
4) Output at Sensor Error : In case of sensor error such as open wire/short, it sets ON/OFF status of the related output.
5) Manual Output Mode : OFF : Output by PV / ON : Output by MVI (-R4 model)
※
※
6) Manual Output Value Setup : It outputs continuously regardless of PV. if manual output value is ON when manual output mode is ON. (-R4 model)
Setting 2 Group Table
NO
DESCRIPTION
500
Select Lock Function
501
Sensor input mode
504
Correction of temperature sensor (※7)
505
Decimal Point(PV) Display (※8)
506
Correction of PV
507
Sensor Input Filter (※9)
508
Sensor Value Display Cycle
509
Set Value(SV) Unification Mode
510
Communication Address (-R4 model)
511
Communication Speed (-R4 model)
Analogue Trans. Output(4~20mA) Mode
512
(-A1 model )
513
Analogue Trans. Output (20mA) (-A1 model)
514
Analogue Trans. Output (4mA) (-A1 model)
※
7) Correction of temperature sensor: It is displayed when sensor input mode(IN) set to Temperature & Humidity control mode or humidity control and temperature display mode.
※
8) PV Decimal Point Display : In case of setting as '1', it displays the current value with cutting the decimal place.
9) Sensor Input Filter Value : It avoids hunting by giving temperature measuring delay.
※
Select Lock Function
Lock cancel
Setting 1group
Setting 1, 2group,
temp. setup lock
Sensor input mode
Use for humidity only
Use for tempeature only
Use for humidity and temperature control
Use for humidity control and
temperature display
Correct PV (Temperature value)
It is only displayed in case of displaying both
humidity and temperature, correct the accuracy
of the temp. sensor
e.g) If displayed temp. is 19℃ and I/O temp is
18℃, it is corrected by inputting -1.0℃
Decimal Point Display
Select decimal point display method
Display 1st decimal place
Display computing of 1/10
Correct PV (Present value)
Correct the accuracy of sensor
e.g) If displayed humidity is 19% and I/O
humidity is 18%, it is corrected by inputting -1.0%
Sensor Input Filter
In case of frequent hunting of the present value,
it is corrected by increasing filter value.
CODE
UNIT
OFF
T Y 1~ 2
AL1
AL2
D F 1~ 2
T P 1~ 2
Sec.
D T 1~ 2
Sec.
F T 1~ 2
Sec.
N T 1~ 2
S F 1~ 2
H Y 1~ 2
A P 1~ 2
ALA
U H 1~ 2
U L 1~ 2
M D 1~ 2
M V 1~ 2
CODE
UNIT
Lock cancel
:
L O C
Setting 1, 2 group
:
Use for humidity
I N
H
control only
T C R
℃
D P
K
C O R
SEC
S F T
SEC
S D T
S T O
OFF
Individual SV(Set value) mode
:
-
A D R
B D R
48 : 4800BPS, 96 : 9600BPS, I92 : 19200BPS, 384 : 38400BPS
PV
:
PV Trans.
A O M
Dehumidification(Cooling)
ReV :
proportional Control
-
R T H
-
R T L
Essential parameter for operation
STEP
MIN
: Dehumidification
: Humidification
H
:
C
No use
(Cooling)mode
(Heating)mode
:
:
Deviation high limit alarm
AL3
Deviation high, low limit alarm
:
AL4
:
Deviation low limit alarm
Deviation high, Low limit reverse alarm
K
0.1
-19.9
P :
+Deviation
1
1
1
/ 0N
K
0.1
ALB
ALC
:
:
:
General alarm
Maintain alarm
Standby alarm
-
1
U L 1~ 2
-
1
-50
/ 0N
/ 0N
Essential parameter for operation
STEP
MIN
Setting 1 group
:
lock
Setting 1, 2group, temp. setup lock
:
Use for temp.
Use for humidity and
T
HT
control only
temperature control
0.1
-19.9
0
1
: I
.
. 0
0.1
-19.9
0.1
0.1
0.1
0
0N
:
1
1
Humidification(Heating)
D IR :
proportional Control
ST1,ST2 :
1
-199
1
-199
Sensor Value Display Cycle
Set the current temp. display cycle.
Setup Value Step Control.
Input SV1(Set Value1) and SV2(Set Value2) separately.
Only input SV1(Set Value1), then SV2(Set Value2)
automatically will be input.
SV1(Set Value1) -> SV2(Set Value2)
Communication Address (-R4 model)
Set communication address.
Communication Speed (-R4 model)
Set communication speed
Analogue Trans. Output(4~20mA) Mode (-A1 model)
PV(Current value) trans. mode
Humidification(Heating) proportional Control
Dehumidification(Cooling) proportional Control
SV(Set value)1 trans. mode
SV(Set value)2 trans. mode
Analogue Trans. Output (20mA) (-A1 model)
Set max. value. of analogue transmission output (20mA)
Analogue Trans. Output (4mA) (-A1 model)
Set min. value. of analogue transmission output (4mA)
The second parameter for optimal operation
MAX
DEFAULT
SBA
:
Sensor open wire alarm
:
AL5
Absolute value high limit alarm
AL6
:
Absolute value low limit alarm
99.9
P N :
±Deviation
0
999
0
999
0
999
0
99.9
ALD
:
Maintain & standby alarm
105
U H 1~2
The second parameter for optimal operation
MAX
DEFAULT
lock
,
Use for humidity control
HTD
and temperature display
99.9
1
:
1
99.9
5.0
5.0
Unifying SV(Set value) Mode
128
SV1,2(Set value) Trans.
999
999
USER SETUP
2.0
P
1
5
5
1.0
100
0
USER SETUP
O F F
H
0.0
0.1
0.0
2.0
1.0
O F F
1
96
PV
100
0