Programming and deleting the RFID cards
6.1
Manual programming of the RFID cards
When delivered from the factory, the Touch Line video outdoor panels do not have access cards programmed. In order to have
access in the building after installation, it is mandatory to program the RFID cards.
The RFID access cards are programmed at the outdoor panel, separately for each family and will be stored in the EEPROM
memory of the system central unit (SCU). Maximum 20 cards can be programmed for each family. The programming procedure
is the following:
The entire video door system is installed and set under tension.
0
Go to the place where the SCU central unit of the installation is mounted.
1
Long press (2-3 sec.) the PROG button
Return to the oudoor panel with the RFID cards allocat e d separately for each family.
Cards programming for Fam. 1:
- Long press (2-3 sec.) the Fam. 1 key
- Briefly approach every card to the area marked with
issues two short beeps.
- After storing all the cards for Fam. 1, to end the programming for the respective family, short touch the
next family key
*For 1 Fam. panels, go to step 3.
2
Cards programming for Fam. 2:
- Long press (2-3 sec.) the Fam. 2 key
- Briefly approach every card to the area marked with
two short beeps.
- After storing all the cards for Fam. 2, to end the programming for the respective family, short touch the
next family key
Repeat the same steps for Fam. 3, Fam. 4, Fam. 5, etc.
Go back to the place where the SCU central unit of the installation is mounted.
3
Short touch the PROG button
Note 1: Follow the same procedure for subsequent programming: card additions or changes.
6.2
Deleting the RFID cards
The cards are deleted separately for each family. The deletion procedure is the following:
The video door system is functional, set under tension.
0
Go to the place where the SCU central unit of the installation is mounted.
1
Long press (2-3 sec.) the PROG button
Cards deleting for Fam. 1:
- Long press (2-3 sec.) the Fam. 1 key
- Short touch the Fam. 1 key seven times
- Long press (2-3 sec.) the Fam. 1 key
Cards deleting for Fam. 2:
2
- L ong press (2-3 sec.) the Fam. 2 key
- Short touch the Fam. 2 key seven times
- Long press (2-3 sec.) the Fam. 2 key
Repeat the same steps for Fam. 3, Fam. 4, Fam. 5, etc.
Go back to the place where the SCU central unit of the installation is mounted.
3
Short touch the PROG button
Note 2: The SCU central unit automatically exits the programming mode, after 5 min. from the last programming action.
The red LED turns on.
Long beep.
Three short beeps confirmation.
Long beep.
Three short beeps confirmation.
The red LED turns off.
The red LED turns on.
Long beep.
Two short beeps confirmation.
Long beep.
Long beep.
Two short beeps confirmation.
Long beep.
The red LED turns off.
. For each programmed card, the panel
. For each programmed card, the panel issues
EN