3.3 Sensor configuration

There are a number of sensor characteristics which can be set via command which have been defined as
configurations.
Configurations are:
Measuring mode (absolute measurement or relative measurement within the Teach range)
Output format when using permanent periodical measurement (ASCII or Binary)
Sensor sensitivity (Sensors with beam columnator)
Number of averagings
Temperature compensation on, off
Teach-in of Sdc and Sde
When leaving production a sensor is pre-configured with its factory settings. These factory settings can be
restored using a special command which overwrites the currently set configuration.
Principle
The functionality of the sensors as well as the output format of the data measured can be set by means of
the configuration commands.
Once the configuration has been carried out the data measured can be retrieved. It is provided according to
the configuration set after every request for data sent. The chosen configuration is stored in a non-volatile
memory and is not lost in a power down situation.

3.4 Factory configurations

Ex factory the sensor is shipped with the following pre-set configurations:
Measuring mode:
Output format:
Sensitivity level:
Number of averagings:
Temperature compensation:

3.5 Commands

(ßß represents the check sum; address 0 is always used in this case)
Reset
R
Bedienungsanleitung_Series09-US_RS232_V1_e.doc
26.03.2013 14:43:00/tof
B (relative)
A (ASCII)
A (Sensors with beam columnator)
C (4 averagings)
0 (off)
{0R}
{0RV000019ßß} None
This command stops all periodical
data issues.
The sensor responds with its
software version (e.g. 000608)
and with its address (0 in this case)