Temperature compensation
The temperature compensation has been designed in to compensate the dependance of the speed of sound
on temperature. Provided the temperature compensation is ON changes induced by varying environmental
temperature are compensated to 2% of So (So = distance from sensor to object). Note: the compensation
becomes active only 15 minutes after the power has been applied. When the temperature compensation is
switched OFF, the sensor measures immediately and correctly at room temperature. Is the environmental
temperature changing a measurement error of 0,18% Sde/K occurs.
Format of the „Get Configuration" data output
Measuring mode
Output format
Sensor sensitivity
Number of averages
Temperature compensation
P-Code
SW document number
Software version
Identification
Format of „Set Configuration"
Measuring mode
Output format
Sensor sensitivity
Number of averages
Temperature compensation
Bedienungsanleitung_Series09-US_RS232_V1_e.doc
26.03.2013 14:43:00/tof
1 Byte
1 Byte
1 Byte (Sensors with beam columnator)
1 Byte
1 Byte
4 Byte
6 Byte
6 Byte
2 Byte
1 Byte
1 Byte
1 Byte (Sensors with beam columnator)
1 Byte
1 Byte