Baumer Hubner Berlin CANopen PMG 10 Руководство по установке и эксплуатации - Страница 21
Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Медиаконвертер Baumer Hubner Berlin CANopen PMG 10. Baumer Hubner Berlin CANopen PMG 10 28 страниц. Absolute encoder with magnetic sensing
ELECTRICAL CONNECTION / SPEED SWITCH AND ADDITIONAL OUTPUT INCREMENTAL
)
5.2.5
Cable connection
To ensure the speciied protection of the device the correct cable diameter must
be used�
Connecting cables are not in scope of delivery�
Cable shield
MB251EN - 11173962, 16A1, Baumer_PMG10-CANopen_II_EN
19
18
22 mm
Mt = 2-3 Nm
TX 20
17
16
16
Terminal box cover
17
Torx and slotted screw,
M4x32 mm
18
Cable gland M20x1�5 mm
for cable ø5-13 mm
19
Connecting terminal,
core cross-section ≤1.5 mm
Connecting cable
ø5-13 mm
Connecting terminal [ B ]
Speed switch/additional output
See
section 5.2.6.1
section
5.2.6.2�
2
or
18/25