Baumer Hubner Berlin HMG 11 Инструкции по монтажу и эксплуатации - Страница 21

Просмотреть онлайн или скачать pdf Инструкции по монтажу и эксплуатации для Медиаконвертер Baumer Hubner Berlin HMG 11. Baumer Hubner Berlin HMG 11 40 страниц. Absolute encoder ethercat
Также для Baumer Hubner Berlin HMG 11: Руководство по установке и эксплуатации (48 страниц), Руководство по установке и эксплуатации (40 страниц), Инструкции по монтажу и эксплуатации (36 страниц)

Baumer Hubner Berlin HMG 11 Инструкции по монтажу и эксплуатации
ELECTRICAL CONNECTION / SWITCHING CHARACTERISTICS SPEED SWITCH (OPTION)
5.6
Switching characteristics speed switch (option)
i
The factory setting of the switching speed for the HMG10P is 6000 rpm� The HMG10
without programming interface is delivered with the individually ordered fixed swit-
ching speed�
Event
During initialisation
After initialisation and
speed ≤ -ns (off)
-ns (off) < speed ≤ -ns (on)
-ns (on) < speed < +ns (on)
+ns (on) ≤ speed < +ns (off)
+ns (off) ≤ speed
High resistance
Resistance between
SP+ and SP-
Low resistance
n
= Speed
+ns (off) = Switch-off speed at shaft rotation in positive rotating direction*
-ns (off) = Switch-off speed at shaft rotation in negative rotating direction*
Switching hysteresis
+ns (on) = Switch-on speed at shaft rotation in positive rotating direction*
-ns (on) = Switch-on speed at shaft rotation in negative rotating direction*
* See
section 7, page
MB244EN - 11171691, 19A2, Baumer_HMG10-SSI_II_EN
-n
-ns (off)
: 5...100 % (factory setting = 10 % min. 1 Digit)
26�
State of the speed switch output
High resistance (overspeed)
High resistance (overspeed)
State unchanged
Low resistance (no overspeed) after initialisation if
the device is rotating between the switching range
during initialisation�
Low resistance (no overspeed)
State unchanged
Low resistance (no overspeed) after initialisation if
the device is rotating between the switching range
during initialisation�
High resistance (overspeed)
-ns (on)
0
+ns (on)
+ns (off)
+n
17/35