Baumer Hubner Berlin microGen PMG10 EtherCAT Руководство по эксплуатации - Страница 28

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Медиаконвертер Baumer Hubner Berlin microGen PMG10 EtherCAT. Baumer Hubner Berlin microGen PMG10 EtherCAT 36 страниц. Absolute encoder

7
|
Disassembly
7.1

Uninstall when using EURO flange B10

7.1.1

Uninstall encoder from drive shaft

DANGER
Burns caused by heat
The device heats up at high speeds. There is a risk of getting burned after use.
a) Avoid overheating the device.
b) Wear suitable protective gloves and clothing.
Ill. 15: Uninstall encoder, mounting device and coupling
1
Coupling
3
Attachment device, customized
Tools
2.5 mm
n
n
28
1
10 mm
Operating Manual
2
3
2
Mounting screw M6x16 mm for attach-
ment device (ISO 4017)
Baumer Hübner
PMG10 & PMG10P EtherCAT | V1