Baumer Hubner Berlin PMG 10 Proibus DP Руководство по установке и эксплуатации - Страница 12

Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Медиаконвертер Baumer Hubner Berlin PMG 10 Proibus DP. Baumer Hubner Berlin PMG 10 Proibus DP 28 страниц. Absolute encoder with magnetic sensing

MOUNTING
4.4
Maximum permissible mounting tolerance when the Baumer Hübner K 35 spring
disk coupling is used
Encoders should be driven through the Baumer Hübner K 35 spring disk coupling (acces-
)
sory), that can be pushed onto the shaft without axial loading.
The encoder must be mounted on the drive with the least possible angular error
)
and parallel misalignment.
Risk of damaging the ball bearings
Coupling components must not be driven onto the shaft with improper force (e. g.
hammer impacts), because of the risk of damaging the ball bearings.
Admissible
parallel misalignment
* For insulated hub version
All dimensions in millimeters, unless otherwise stated.
9/25
2-10
Admissible
angular error
MB247EN - 11171697, 16A2, Baumer_PMG10-ProibusDP_II_EN
Admissible
axial movement
±0.7 (±0.3*)