Baumer OM20 Руководство по эксплуатации - Страница 13

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Измерительные приборы Baumer OM20. Baumer OM20 48 страниц. Laser distance sensors

Baumer OM20 Руководство по эксплуатации
Baumer
Teaching the zero position
Instruction:
a) Press the teach button briefly.
ü
Green and yellow LEDs light up (teach button is active). If the LEDs do not light up, start
the sensor again.
b) Keep the teach button pressed for 2 seconds.
ü
Green LED blinks with 2 Hz.
c) Place the measurement object on the desired position for the zero point and briefly press
the teach button within 60 seconds.
Result:
ü
Teach-in OK: Green and yellow LEDs light up briefly. Afterwards, the sensor goes back to
operating mode.
ü
Teach-in not OK: Green and yellow LEDs blink simultaneously with 8 Hz.
After the zero point is shifted,
the digital measured values before the zero point (in the direction of the sensor) are output
n
as negative and those after the zero point are output as positive measured values.
the limits of the analog measurement field have shifted. Therefore, parameterize the analog
n
measurement field again.
Resetting to the factory settings
Instruction:
a) Press the teach button briefly.
ü
Green and yellow LEDs light up (teach button is active). If the LEDs do not light up, start
the sensor again.
b) Keep the teach button pressed for 8 seconds.
ü
Yellow and green LEDs blink simultaneously with 2 Hz.
Result:
ü
Teach-in OK: Green and yellow LEDs light up briefly. Afterwards, the sensor goes back to
operating mode.
ü
Teach-in not OK: Yellow and green LEDs blink simultaneously with 8 Hz.
OM20/OM30 | V1
Sdc
ZP
P1
-
+
measurement field
Sde
P2
Analog
Operating Manual
Description
|
3
13