Baumer TA201 Руководство по эксплуатации - Страница 28

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Измерительные приборы Baumer TA201. Baumer TA201 36 страниц. Electronic

TA201
Line 1
Line 2
Line 3
Modifying the status ➜ Enter the respective status number using the keys
Line 11
Line 12
Line 13
28
Programming field 1
For information on the displays and on modification of the individual
values see chapter 4.
Press the key
Select the operating parameters. The respective LED flashes.
F1 - display tachometer 1
F2 - display tachometer 2
F3 - display for the measurement function
After completion of the first programming field a dotted line ap-
pears in the display.
Programming field 2
In the second programming field the letters „StAt" appear, standing
for status selection.
„StAt" appears in the display. The LED for the respective opera-
ting parameter flashes.
Meaning of the status numbers
0
Operating parameter can be selected, readed and deleted in
the operating mode.
1
Operating parameters can be selected and readed in the
operating mode.
2
Operating parameter is completely disabled for the operating
mode. If this operating parameter is selected it is not dis-
played on the operating mode but bypassed. The respective
function is retained.
The altered status number is automatically stored when the next
programming line is selected.
Press the key
The status of every operating parameter is selected in sequence.
F1 - display tachometer 1
F2 - display tachometer 2
F3 - display of measurement function
After completion of the second programming field a dotted line
appears in the display.
The default operating parameter status is zero.
www.baumerivo.com
again.
again.
and
.