Doulton HIS Инструкции по установке
Просмотреть онлайн или скачать pdf Инструкции по установке для Системы фильтрации воды Doulton HIS. Doulton HIS 2 страницы. Push-fit filter
HIS Push-Fit Filter
Installation and
Conditioning Instructions
Parts & Service Availability:
Important – Always use genuine Doulton
components to guarantee the manufacturer's performance claims.
Contact your local Doulton
®
distributor for sales, service, replacement parts and for
the range of available replacement filter elements.
1.
Installation
Note – The filter cannot be used for the treatment of hot water and should only be
connected to the cold water supply.
1.1 Selecting a Position for the Filter
The filter should be fixed inside a unit or to a wall with the screws and bracket
provided, near to the incoming water supply and the user tap. Make sure that the
filter is located so that the connecting pipework does not have any sharp bends
in it. For easy servicing of the filter there should be at least 4 inches of
clearance below the body of the filter to allow for removal of the filter element
for cleaning or renewal.
replacement filter elements and
®
1.2 Connecting Pipework & Fittings
The filter is supplied with 3/8" (inch) pushfit connections. Medium density
polyethylene tubing is recommended.
Important - Tubing must conform to the following tolerances:
Tubing Dimensions:
Head Type
Nominal
3/8"
3/8"
An isolation valve and non-return valve should be fitted upstream of the filter (these
are required by law in the UK). The isolation valve may be used to regulate the
maximum flow rate in accordance with the requirements of the filter element used.
Having selected the appropriate fittings, a user tap should be installed in
accordance with the manufacturer's instructions in a convenient position and then
connected to the filter.
1.3 Assembling and Fixing the Filter
Fit the bracket to the filter head using the 4 retaining screws provided and then
having chosen a position for the water filter, mark the position of the bracket fixing
screws onto the wall/unit.
Attach the filter head to the wall/unit with the 2 fixing screws provided.
With the water supply isolated connect the upstream and downstream pipework
to the filter head ensuring that the arrow on the top of the head is showing the
correct direction of flow and that piping/fittings are pushed into the push fittings to
a minimum of 18mm (.75") depth.
Ensure that a sealing washer is fitted onto the filter element threaded mount stem
and screw the filter element into the filter head until washer resistance is felt. Do
not over-tighten.
If there is less than 10 inches clearance below the base of the filter housing, place
the filter body in position over the filter element before screwing the filter element
into the head.
Moisten the O ring on the filter body, check that it is located correctly and then
screw the filter body to the filter head. Hand tighten only.
2.
Conditioning the Ceramic Filter
The filter system should now be ready for pressurisation. With the user tap in the
on position, gradually open the upstream isolation valve until the flow from the tap
has stabilised at the recommended flow rate.
Close the user tap and ensure that the system is watertight.
In order to remove any loose particles resulting from the manufacturing process or
from cleaning the filter element, it is recommended that the first supply of filtered
water should be run to waste for 10 minutes.
www.doulton.com
Tolerance
+
-
.001"
.004"
A GENUINE
WATER FILTER
A GENUINE WATER FILTER