Baumer SXC10c Руководство пользователя - Страница 42

Просмотреть онлайн или скачать pdf Руководство пользователя для Цифровая камера Baumer SXC10c. Baumer SXC10c 48 страниц. Sxc series cameralink cameras with truesense imaging sensors
Также для Baumer SXC10c: Краткое руководство по эксплуатации (2 страниц)

Baumer SXC10c Руководство пользователя
Figure 42 ►
Tap geometry 1X-1Y.
The pixel information
is  transmitted  pixel-by-
pixel and line-by-line.
Figure 43 ►
Tap geometry 1X2-1Y.
Figure 44 ►
Tap geometry 1X3-1Y.
42

9.4.2. Tap Geometry

Since frame grabbers possess the ability of image reconstruction from multi-tap cameras
"on-the-fly",  the  CameraLink
ported tap geometries from the manufacturers of both, cameras and frame grabbers.
9.4.2.1.
Single
Tap Geometry
For single tap transmission the cameras of the Baumer SXC series employ the 1X-1Y tap 
geometry:
9.4.2.2.
Dual
Tap Geometry
For dual tap transmission the cameras of the Baumer SXC series employ the 1X2-1Y tap 
geometry:
9.4.2.3.
Tripple
Tap Geometry
For triple tap transmission the cameras of the Baumer SXC series employ the 1X3-1Y tap 
geometry:
  standards  demands  the  specification  of  the  used  /  sup-
®