Amphenol ePower-lite C10-738986-2XS2 Инструкция по монтажу кабеля - Страница 6

Просмотреть онлайн или скачать pdf Инструкция по монтажу кабеля для Кабели и разъемы Amphenol ePower-lite C10-738986-2XS2. Amphenol ePower-lite C10-738986-2XS2 12 страниц. 5.7mm 2 port connector

Amphenol ePower-lite C10-738986-2XS2 Инструкция по монтажу кабеля
Step 10:
Repeat steps 7 and 8 and 9 to assemble another contact assembly.
Step 11:
Pull one of the wires out and load. Crimp the Rear Shield (Part 5).
Cable Size
16 mm
2
25 mm
2
Notes: The recommended crimp sizes are only for reference. The customer should adjust them according to cable
specification and crimp tool and test results including contact resistance and pullout force.
Crimping tool: Hydraulic press
Step 12:
Repeat step 11 to assemble another Rear Shield.
length: 24.2 - 25.5mm
Recommended crimp
length of Side S
6.0
6.0
Recommended crimp
length is 3.5±0.5mm
Recommended crimp
dist across Flats F
11.5±0.1mm
11.5±0.1mm
Recommended Min. Cable
Pullout Force (N)
150
150
6