Baumer FLDK 110G1006/S14 Руководство пользователя - Страница 23
Просмотреть онлайн или скачать pdf Руководство пользователя для Кассовый аппарат Baumer FLDK 110G1006/S14. Baumer FLDK 110G1006/S14 35 страниц. Laser copy counter
10.2
Electrical data
Operating voltage V
S
Limits:
reverse-protected
Ripple V
S
Power consumption
Current consumption
Average:
Peak (after switching on)
Output connector
FLDK.../S14
FLDK.../S42
FLDK110x10/xxxxxx
Output circuit
FLDK 110G...
normal state
FLDK 110C...
switchable voltage
load resistance
current load:
short-circuit protected
Output pulse length
FLDK...1003/...and ...1005/...
FLDK...1006/... and ...1303/...
Manual SCATEC-2
Version 2021-09
+10 VDC to +30VDC (UL-Class 2)
yes
10% within the limits of V
< 2 W
< 170 mA
< 180 mA
M12 connector, 5-pole
DIN 45322, 6-pole
see section 14
Push-pull
low
Opto-isolated
maximum 40 V
maximum 50 kOhm
max. 100 mA
yes
5, 10, 15, 20 ms selected by DIP switch
5, 10 ms selected by DIP switch
23
www.baumer.com
S
Baumer Electric AG
Frauenfeld, Switzerland