Baumer NE215 Руководство по эксплуатации - Страница 7

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Кассовый аппарат Baumer NE215. Baumer NE215 40 страниц. Electronic preselection counter

Baumer NE215 Руководство по эксплуатации
Counter connect
115 VAC 230 VAC
7
8
9
6
5
4
11 10
3.1
Connecting the power supply
For power supply following voltage ranges are available:
AC 115/230 VAC (50/60 Hz)
DC 24 VDC ±10%
Voltage supply
115/230 VAC
24 VDC
➜ Assign voltage supply to terminals 2 and 3 according to
diagramm.
DC-voltage 24 VDC:
Connect voltage supply that is free from any interference. Do not uti-
lize the voltage supply for parallel supply of drives, shields, magnetic
valves, etc. Supplying lines must be separated from lines providing
load current.
Fire protection: Operate the instrument using the recommended
external fusing indicated in the terminal diagram. EN 61010 specifies
that 8 A/150 VA (W) must never be exceeded in the event of a fault.
3.2
Assignment signal output „relay contact"
Terminals 4, 5, 6 and 7 , 8, 9 are no-potential changeover contacts.
Terminals 10 and 11 are configured as NC or NO contacts in ac-
cordance with the purchase order specification. The signal outputs
can be assigned in accordance with the adjoining wiring diagram.
Implementation as a pulse or continuous signal, together with the
pulse time, is effected in the programming mode (lines 31, 32, 33).
Max. rating
150 VA/30 W
The user is responsible for ensuring that a switching load of 8 A/150
VA (W) is not exceeded in the event of a fault. Internal spark sup-
pression by means of two zinc oxide varistors (275 V).
➜ Assign terminals 4, 5, 6; 7 , 8, 9; and 10, 11 (relay contactoutputs)
accordingly.
Recommended external fuse
M 125 mA
M 400 mA
Max. voltage
265 V
NE215
Max. current
1 A
7