Dover Blackmer TLGLF3C Инструкции по установке, эксплуатации и техническому обслуживанию - Страница 6
Просмотреть онлайн или скачать pdf Инструкции по установке, эксплуатации и техническому обслуживанию для Водяной насос Dover Blackmer TLGLF3C. Dover Blackmer TLGLF3C 12 страниц. Liquefied gas pumps
Failure to set the vehicle emergency
brake and chock wheels before
performing service can cause severe
personal injury or property damage
Hazardous
machinery can
cause serious
personal injury.
Failure to disconnect and lockout
electrical power or engine drive before
attempting maintenance can cause
severe personal injury or death
Hazardous
machinery can
cause serious
personal injury.
Disconnecting fluid or pressure
containment components during pump
operation can cause serious personal
injury or property damage.
Hazardous pressure
can cause personal
injury or property
damage
LUBRICATION
NOTICE:
To avoid possible entanglement in moving parts do not
lubricate pump bearings, hydraulic adapter coupling or
any other parts while pump is running
Pump bearings and hydraulic motor couplings (if equipped)
must be lubricated every three months at a minimum. More
frequent lubrication may be required, depending on the
application and the operating conditions.
Recommended Grease:
Exxon® - Ronnex MP Grease
Mobil® - Mobilith AW2 (64353-6) Grease, or equivalent
Lithium grease.
MAINTENANCE
Hazardous pressure
can cause serious
personal injury or
property damage
Hazardous or toxic
fluids can cause
serious injury.
Greasing Procedure:
1.
Remove the grease relief fittings (76A) from the bearing
covers (27) or hydraulic motor adapter (135).
2.
SLOWLY apply grease with a hand gun until grease
begins to escape from the grease relief fitting port. Discard
excess grease in accordance with the proper codes and
regulations.
3.
Replace the grease relief fittings (76A).
DO NOT over grease pump bearings. While it is normal for
some grease to escape from the grease tell-tale hole after
lubrication, excessive grease can cause mechanical seal
failure. The tell-tale hole is located in the head (20) between
the bearing (24) and the mechanical seal (153).
501-D00
Page 6/12
Failure to relieve system pressure prior
to performing pump service can cause
serious personal injury or property
damage. Systems with meters will still
be pressurized even after the hose is
emptied
If pumping hazardous or toxic fluids,
system must be flushed and
decontaminated, inside and out, prior to
performing service or maintenance
NOTICE:
Maintenance shall be performed by
qualified technicians only, following the
appropriate procedures and warnings
as presented in this manual.