Dover PSG MOUVEX SUBMERGED AM UNIT ON PLATE Установка, эксплуатация и обслуживание - Страница 6
Просмотреть онлайн или скачать pdf Установка, эксплуатация и обслуживание для Водяной насос Dover PSG MOUVEX SUBMERGED AM UNIT ON PLATE. Dover PSG MOUVEX SUBMERGED AM UNIT ON PLATE 13 страниц. Submerged am unit on plate
4. DIRECT DRIVE BY MOTOR (continued)
Start the pump empty to check that the connections are
good and that the direction of rotation corresponds to the
system intake and discharge directions. If it is necessary
to reverse the direction of rotation, follow the instructions
below :
Three-phase motor : switch any 2 current input wires.
Bi-phase motor : switch two same phase wires.
Single-phase motor : follow the instructions on the notice
supplied with the motor.
• Motor provided as an option.
- Technology : internal gear, Gerotor
- Capacity : 100 cm
3
- Flowrate requested : 57 l/min
- Pressure requested : 130 bar
NT 1010-I00 03 18 Submerged AM unit on plate e
5. DRIVE BY HYDRAULIC MOTOR
4.3 Diesel engines drive
CAUTION
Excessive temperature-
can cause injury
or severe damage.
Do not forget that these engines are not reversible. It is
therefore vital to carefully check the inlet and outlet sides
of the pump before connecting the pump unit to the piping.
The use of diesel engines drive is now well known.
Nevertheless, we strongly recommend that you carefully
read the technical manuals concerning them.
6/13
THE SURFACES OF THE PUMP CAN
BE AT A TEMPERATURE LIABLE TO
CAUSE INJURY OR SEVERE DAMAGE.