Amphenol Procom PRO-DAR16 Руководство пользователя - Страница 15

Просмотреть онлайн или скачать pdf Руководство пользователя для Приемник Amphenol Procom PRO-DAR16. Amphenol Procom PRO-DAR16 15 страниц. 19” rack-mountable dual amplifier receiver multicoupler

However, if any malfunction of the multicoupler RF amplifier system occurs, the POWER LED
on the front plate will immediately light with flashing red color and indicate that some fault
condition has occurred.
Please refer to chapter 9: "Trouble shooting" below.
If the instructions in the Trouble shooting chapter is insufficient, please contact nearest
PROCOM dealer or Amphenol Procom for further information.

9 Trouble shooting

Symptom
POWER LED off
AC or DC fuse blown,
POWER LED off
AC fuse blown
DC fuse blown
Reduced receiver
sensitivity
POWER LED lights
with flashing red light
Other fault symptoms
9.1

Spare Parts

Article
Fuse for 230 VAC
Fuse for 115 VAC
Fuse for 12 VDC/24 VDC
Fuse for 48 VDC
Phoenix cable connector 7.62 mm
female for DC supply connection
Phoenix cable connector 5.08 mm
female for ALARM connection
Possible cause
Supply voltage not
connected or off.
Internal circuitry fault
By DC voltage
operation, wrong DC
polarity.
Supply voltage not
connected or off.
Internal amplifier fault
Value
T315mAL250V 5x20 mm
T500mAL250V 5x20 mm
T2AL250V 5x20 mm
T315mAL250V 5x20 mm
Page 15 of 15
Action
Connect supply voltage.
Check and replace fuse(s).
Contact Amphenol Procom.
Check DC voltage and polarity and
reverse connections if necessary.
Connect supply voltage.
Contact Amphenol Procom.
Contact Amphenol Procom.
Amphenol
Procom
Spare part no.
661001008
661001096
661000047
661001008
662001103
662001102