Disassembly instructions for periodic cleaning

Dispense chute cover removal
1. Remove top cover.
2. Push chute cover up vertically to slip off
holding tab.
3. After clearing tab, pull chute cover forward
to remove.
Dispense mechanism assembly
removal
1. Remove top cover.
2. Remove chute cover (see above).
3. Remove auger motor assembly (see above).
4. Remove quick release pins from the ice chutes
and gates, then unplug wires from solenoids.
5. Lift dispense mechanism up and off auger tube.
Auger and auger tube removal
(Fig. 3)
1. Remove auger motor and dispense mechanism
assembly (see above).
2. Pull auger upward to clear auger tube.
3. Lift auger tube upward to clear dispenser top.
4. Slide tube and bearing plate through auger
tube gasket.
Dispense wheel removal
1. Remove drain pan assembly and bin access cover.
2. Remove center thumbnut and threaded rod on
dispense wheel assembly and lift wheel out front
access opening.
Auger motor assembly removal
1. Remove top cover.
2. Remove one thumbnut on rear of motor bracket.
3. Lift motor bracket up and unplug electric
quick disconnects.
4. Remove motor assembly.
Fig. 1
drain pan
assembly
Fig. 2
Dispense assembly, top view
10
Front view
right-hand unit
top cover
right-hand unit
quick
release
pin
chute
cover
dispense
chute
solenoid
gate
ice chute