Follett HMC1010WBS Руководство по установке - Страница 9

Просмотреть онлайн или скачать pdf Руководство по установке для Льдогенератор Follett HMC1010WBS. Follett HMC1010WBS 17 страниц. Ice storage bins

Follett HMC1010WBS Руководство по установке
Connect utilities to louvered docking assembly.
6.1
Air-cooled ice machines only
2 ft. x 1" OD
silicone tubing
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1" Stand pipe/Drain
• Rough-in ice machine potable water
supply
.
3/8" push-in connection will be made at
shut-off valve inside machine
• Remove access panel if necessary
• Connect the silicone tubing to the ice
machine 3/4" drain barb
• Assemble the 3/4" barb x 3/4" FPT to the
3/4" MPT x 1" slip. Connect the other end
of the silicone tubing to the 3/4" barb
• Connect the 1" slip fitting to the 1" stand
.
pipe/drain
Note: Minimum 8" radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
• Apply Petrol-gel to barbed drain fitting
• Replace access panel.
BIN • RIDE Technology
Minimum 8"
radius
.
.
.
self-contained

External connections

6.2
Water-cooled ice machines only
3/4" barb x 3/4" FPT
• Rough-in ice machine potable water
supply
.
3/8" push-in connection will be made at
shut-off valve inside machine
• Remove access panel if necessary
• Connect the silicone tubing to the ice
machine 3/4" drain barb
• Assemble the 3/4" barb x 3/4" FPT to the
3/4" MPT x 1" slip. Connect the other end
of the silicone tubing to the 3/4" barb
• Connect the 1" slip fitting to the 1" stand
pipe/drain
.
Note: Minimum 8" radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
• Connect cooling water supply
return
• Apply Petrol-gel to barbed drain fitting
• Replace access panel.
6
Minimum 8"
radius
2 ft. x 1" OD
silicone tubing
3/4" MPT x 1" slip
1" Stand pipe/Drain
.
.
.
and
9