11.
rinse components previously cleaned
12.
remove the stick that holds the floating valve
13.
connect appliance to mains electricity supply, and switch on
14.
rinse evaporator leaving appliance running for at least 5 minutes
15.
prepare to perform the sanitizing operations described in the next chapter
3 SANITIZING
Use a 200 mg/l solution of sodium hypochlorite and water (or a solution of ½ ounce of normal bleach to 1 gallon
of water) or one of the solutions commonly used to disinfect babies' feeding bottles; in this case, check that the
sanitizing product is:
•
authorized by your country's Ministry of Health
•
suitable for use with food machines
•
not harmful to the materials and components of this appliance
For the directions for use and concentrations, please refer to those shown on the packaging and recommended
by the manufacturer. We recommend using the solution at the temperature of 25°C.
1.
empty water basin
2.
fill water basin with a with sanitizing solution. Raise without forcing the floating valve with a non-
metallic stick
3.
switch on the appliance and let it run, topping up the level of the solution in the basin until at least 2
litres of solution has been used
4.
switch off appliance and disconnect from power supply mains
5.
remove all ice from bin
6.
wipe ice outlet (1 in Fig. 4), bin and door with sanitizing solution, using a sponge and a soft brush
7.
rinse ice outlet, bin and door thoroughly with cold water
8.
remove the stick that holds the floating valve
9.
connect appliance to mains electricity supply, and switch on
10.
rinse evaporator leaving appliance running for at least 10 minutes
11.
close lid of water basin
12.
refit rear panel
13.
reposition top, securing it to rear panel with the screw
The ice-cube maker can now be reactivated as specified in the instruction manual.
!! IMPORTANT: All the ice produced during the first five cycles after cleaning and sanitizing operations must be
discarded.