CAUTION: Changing polarity during operation is not recommended.
The output polarity reversal feature may be disabled in all modes by connecting Pin 11 to Pin 10 at the rear
panel remote connector.
Remote Analog Interface Connections:
Signal Pin
1
14
2
15
3
16
4
17
5
18
6
19
7
20
8
21
9
22
10
23
11
24
12
25
13
NOTE
: The center tap voltage monitor is currently set for a 0-5Vdc scale with a nominal 2.5Vdc offset
1
representing 0Vdc actual at the center tap terminal. Thus, the center tap monitor will have a 0Vdc output for -
500Vdc actual at the center tap terminal, and a 5Vdc output for +500Vdc actual at the center tap terminal.
C. Serial Remote Operation
The operation sequence for serial mode is similar to "Local Manual" operation. Full remote operation is
available over serial RS-232C interface via the real panel 9-pin connector (DB9S). The serial interface
provides all of the features found on the front panel menus.
CAUTION: The default communication protocol is factory set at 9600 baud, 8 bits, 1 stop bit, no parity. These
settings can be changed via internal dip switches. Contact Comdel Engineering for assistance if other protocol
settings are required. Any attempt to change factory settings will void any warranty on the unit.
The following is a description of the RS-232 ASCII instruction set to operate the ESC-2.
1.
All incoming instructions need to be terminated with a carriage return (HEX 'D') except for the
ATTENTION (!) and EXIT (#) commands.
2.
The interface does not normally require handshaking for it's input because it is interrupt driven with a 1K
buffer.
© 2006 Comdel, Inc.
Function
Voltage set point, analog return
Voltage set point, analog positive (10V full scale)
Current set point, analog return
Current set point, analog positive (10V full scale)
Output voltage monitor (10V full scale)
Center tap terminal voltage monitor (See NOTE
Positive output current monitor (10V full scale)
Negative output current monitor (10V full scale)
Monitor circuit analog return
HV enable digital input positive (24Vdc digital)
HV enable digital return
Polarity change digital positive (24Vdc digital)
Polarity change digital return
Discharge command digital positive (24Vdc digital)
Discharge command digital return
HV on indicator positive, open collector (40Vdc/50mA max. rating)
HV on indicator negative, open emitter
Output polarity monitor (+15v=pos/0v=neg)
Polarity indicator return/ground
No connection
Polarity disable
+15Vdc source (25mA max.)
+15Vdc source (25mA max.)
Circuit common / 15v return
Circuit common / 15v return
ESC-2/FP Manual
)
1
6