Follett 110CT425W Руководство по установке - Страница 12
Просмотреть онлайн или скачать pdf Руководство по установке для Диспенсер Follett 110CT425W. Follett 110CT425W 17 страниц. Ice and water dispenser
Finish cleaning – SafeCLEAN Plus only
10. If the dispenser is not equipped with a Chilled Water Accessory, skip to Step 11.
a. Remove four screws securing splash panel.
b. Disconnect 3/4" (19 mm) drain line from bottom of chilled water canister.
c. Loosen (do not remove) screw securing front bracket of chilled water canister to bottom of dispenser
hopper.
d. Rotate canister clockwise to release front bracket, then pull canister forward to disengage rear bracket.
e. Remove chilled water coil from canister and clean with cloth wrung out in SafeCLEAN Plus solution.
f. Wipe inside of chilled water canister with cloth wrung out in SafeCLEAN Plus solution.
g. Rinse all above items with damp cloth wrung out in clear water.
h. Reinstall chilled water coil into canister (rubber alignment grommet on coil tubing must be located outside
chilled water canister to hold coil securely against canister wall).
i. Reinstall chilled water assembly on dispenser and tighten screw securing front bracket.
j. Reconnect 3/4" (19 mm) drain line to chilled water canister.
11. Reinstall dispense chutes, wheel, baffle, stud assembly and knurled nuts.
12. Remove top bearing insulation. Loosen Phillips-head screw on nozzle connected to evaporator. Remove
nozzle from evaporator side only, leave other side of nozzle connected to transport tube.
13. Soak one SaniSponge in remaining SafeCLEAN Plus solution.
14. Insert the sponge soaked in cleaning solution into nozzle then insert a dry sponge into the nozzle.
15. Replace nozzle onto evaporator and tighten screw. Ensure drain is connected to reservoir and vent tubes
are connected to evaporator drain pan. Replace top bearing insulation.
16. Turn ON bin signal switch. Wait for ice to push sponges through transport tube.
17. Collect sponges from ice storage bin.
18. Replace hopper lid, machine top, turn ON dispenser power and install front cover.
19. After 10 minutes, dispense all ice and discard.
12
110CT425A/W, 110FB425A/W