Follett Symphony Plus 25 series Руководство по установке - Страница 3

Просмотреть онлайн или скачать pdf Руководство по установке для Диспенсер Follett Symphony Plus 25 series. Follett Symphony Plus 25 series 17 страниц. Ice and water dispensers
Также для Follett Symphony Plus 25 series: Руководство (6 страниц)

Follett Symphony Plus 25 series Руководство по установке
Electrical
§ 115 V, 60 Hz, 1 phase, 11.0A
§ Connect to a 15A dedicated circuit.
§ Furnished with 7 ft (2 m) power cord with a 90° NEMA hospital grade 5-15 plug.
Ambient
Air temp*
Water temp
Water pressure (psi/bar)
* Ambient air temperature is measured at the air-cooled condenser coil inlet.
Ambient water temperature is measured in the ice machine float reservoir.
Plumbing
Dispenser drain
Water inlet
Condenser inlet
Condenser outlet
Note: Water shut-off recommended within 10 ft. (3m) of dispenser. Drain to be hard-piped and insulated. Maintain at
least 1/4" per foot (20 mm per 1 m) run of slope.

Ventilation clearances

Required for ventilation
Suggested for service
Note: Do not block right side air intake or right side air exhaust.

Dry weight

§ 25/50CI425A/W (countertop): 215 lbs. (98 kg)
§ 25/50HI425A/W (wall mount): 230 lbs. (105 kg)
100 F/38 C Max.
50 F/10 C Min. (Best performance below 80 F (27 C)
90 F/32 C Max.
45 F/7 C Min. (Best performance below 70 F (21 C)
70/5 Max.
10/0.7 Min.
Connections 25/50CI425A
Water-cooled 3/8" FPT
Water-cooled 3/8" FPT
3" (77 mm) each side
12" (30.5 cm) top,
6" (15.3 cm ) left side
25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A
Rough-ins 25/50HI425A
3/4" MPT
3/8" FPT
Air-cooled
Air-cooled 3/4" FPT
3/8" FPT
N/A
N/A
Water-cooled
N/A
12" (30.5 cm) top
3