Amprobe AM-45 Руководство пользователя - Страница 8

Просмотреть онлайн или скачать pdf Руководство пользователя для Испытательное оборудование Amprobe AM-45. Amprobe AM-45 9 страниц.

Amprobe AM-45 Руководство пользователя
DC µA Current (AM-47 only)
RANGE
Accuracy
1.5%+3d
400.0µA
1.2%+3d
2000µA
AC µA Current (AM-47 only)
RANGE
Accuracy
50Hz -- 60Hz
2.0%+3d
400.0µA
1.5%+3d
2000µA
Audible Continuity Tester
Open Circuit Voltage: 0.4VDC typical
Audible Threshold:
AM-45 & AM-47: between 50Ω and 300Ω
AM-42: between 10Ω and 120Ω
-------------------------------------------------------------------------

LIMITED WARRANTY

Congratulations! Your new instrument has been quality crafted according to quality standards and
contains quality components and workmanship. It has been inspected for proper operation of all of its
functions and tested by qualified factory technicians according to the long-established standards of
our company.
Your instrument has a limited warranty against defective materials and/or workmanship for one year
from the date of purchase provided that, in the opinion of the factory, the instrument has not been
tampered with or taken apart.
Should your instrument fail due to defective materials, and/or workmanship during this one
year period, a no charge repair or replacement will be made to the original purchaser. Please
have your dated bill of sale, which must identify the instrument model number and serial
number and call the number listed below:
Repair Department
ATP – Amprobe, TIF, Promax
Miramar, FL
Phone: 954-499-5400
Toll Free: 800-327-5060
Fax: 954-499-5454
Website: www.amprobe.com
Please obtain an RMA number before returning product for repair.
Outside the U.S.A. the local representative will assist you. Above limited warranty covers repair and
replacement of instrument only and no other obligation is stated or implied.
Burden Voltage
6mV/µA
6mV/µA
Burden Voltage
6mV/µA
6mV/µA
Non-Contact EF-Detection (AM-45 & AM-47)
Typical Voltage
15V to 55V
30V to 85V
55V to 145V
85V to 190V
above 120V
Indication: Bar graph segments & audible beep tones
proportional to the field strength
Detection Frequency: 50/60Hz
Detection Antenna: Top left corner of the meter
Probe-Contact EF-Detection: For more precise
indication of live wires, use the Red (+) probe for
direct contact measurements
--------------------------------------------------------------------------
Bar Graph Indication
-
- -
- - -
- - - -
- - - - -
P/N: 7M1C-0661-0000
8