MAINTENANCE
The single most important maintenance activity for the Bio Cart 13 is keeping them clean. Since the Bio
Cart will be used in a variety of environments, the degree of cleaning will vary with each environment.
The cleaning protocol for each area that the Bio Cart will be used must be understood prior to
transporting it to those areas. In Operating Room environments, the cart must be totally wiped down
with the proper sanitizer inside and out and all wheel surfaces. In other areas, lesser measures are
required. Consult with the staff in the planned work areas for detailed Infection Control procedures.
Contact Air-Care if you have questions about how to meet specific requirements.
Generally, cleaning the inside of the cart after each use is recommended. With the Air Scrubber
running, the air in the Bio Cart HEPA-UVC 13 is HEPA filtered. It is recommended that the air scrubber
is left running while vacuuming debris off the floor, shelf, ladder and other surfaces.
Wiping down the pleats in the bellows with a damp cloth, inside and out, between all pleated surfaces
is recommended. A suitable biocide can also be used.
The wall surfaces should also be wiped down regularly.
UVC/UVGI Lamps Replacement
The UVC/UVGI lamps have a useful life of 10,000 hours. This is just over 12 months of 24/7 illumination.
In the Bio Cart, they will not be on continuously, but turning them OFF and ON can sometimes reduce
To receive reminders when it is time to change the UVC lights,
visit uvlightwarranty.com to register your lights.
Electrostatic
Material
Disposable
Pad
their useful life. Use the observation window in the Bottom of the Air
Scrubber section to verify that the bulbs are both operating. Register
your Bio Cart and receive reminders to replace the filters and UVC
lamps.
To replace the UVC/UVGI Bulbs, unplug both power cords for the
UVC/UVGI power boxes, just above the Bulb Viewing window.
Remove the 4- screws on the power unit to be re-lamped, and
carefully remove the box and the bulb. Unscrew the bulb with built-in
Cleaning and replacing the Pre-Filters
There are 2 layers for the standard prefilter in the Bio Cart
HEPA-UVC 13 air scrubber unit.
The bottom layer in the filter frame is 1", non-woven, white
polyester. The top layer is black, woven, electrostatic
polypropylene. These are disposable and should both be
replaced when soiled.