Daikin AH093E35AX Техническое руководство - Страница 15

Просмотреть онлайн или скачать pdf Техническое руководство для Кондиционер Daikin AH093E35AX. Daikin AH093E35AX 15 страниц. R410a window air conditioners & heat pumps

Daikin AH093E35AX Техническое руководство

TROUBLESHOOTING

CODE
Outdoor ambient thermostat
1
F1
not registering on the board.
Outdoor ambient thermostat
2
F2
not registering on the board.
Outdoor coil thermostat
3
F4
not registering on the board
Indoor discharge thermostat
4
FJ
not registering on the board
STATUS
CORRECTIVE ACTION
Replace or re-connect the thermostat
Replace or re-connect the thermostat
Replace or re-connect the thermostat
Replace or re-connect the thermostat
15