Silencing an alarm / Alarm Memory

After an alarm is triggered, the control panel begins to send the intruder event alerts to the contacts in the phonebook programmed by the installer. The siren
begins to sound, the red LED on the control panel is lit steadily and the alarm alert is displayed. If the zone is reset, the control panel will show the message
"System in alarm" (fl ashing). Enter a valid user code and disarm the system to silence all the indications.
After disarming, the alarm memory will be shown once and then it will be reset. If the system is not disarmed after an alarm, the system will indicate an alarm
memory condition by means of the red LED fl ashing and the alert "System in alarm" (fl ashing). The user can scroll through the alarm memory using the down arrow.
Generating a fi re / medical / panic alarm
Specifi c button combinations can be used to activate emergency alarms. To program the recipients of notifi cations relating to these alarms, please contact your
installer. To activate the alarms, press the button combinations for approximately 2 seconds.

Walk test

The walk test is used to check zone functions. When the system is in walk test mode, the installer should activate all zones in sequence and the system will emit
an audible signal after every activation. The display will show how many zones have been tested and the total number to test. A confi rmation message will be
displayed when all the zones have been tested. The zones to be tested are selected in the installation menu. The zones with a poor RF signal are listed as missing
zones with the message "LOW!".
Reset
zone
FIRE
Flashing
MEDICAL
Zone
activation
PANIC
All zones
activated
Flashing