amsbio Ozilla AMS.E4002GD Краткое руководство по эксплуатации - Страница 2

Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Датчики безопасности amsbio Ozilla AMS.E4002GD. amsbio Ozilla AMS.E4002GD 6 страниц.

INTRODUCTION
®
The Ozilla
Ozone Gas Detector Pro is the next generation gas detector and a substantial improvement over the original Ozilla
Ozone Gas Detector, both in terms of sensitivity, performance, and options. Just like the original device, the Ozilla Ozone Gas
Detector Pro is portable, rugged, but it also has a vastly improved backlit color display that is easy to read and more user
functions. The Pro device is built with state of the art 32-bit microprocessor and 24-bit
Furthermore, the detector is designed to be user-friendly, and offers many useful functions such as internal data storage, and high
and low alarm settings. The detector has a long operating battery life, and requires little or no maintenance.
Features & Benefits
Rugged and simple easy-to-use design
Broad range from 0.00 to 50.00 ppm (0 ~ 100% Vol)
Backlit high resolution 2.4-inch color LCD display
Rapid and accurate ozone gas level detection
Rechargeable and portable for use in multiple spaces and environments
Water, corrosion, dust and wear resistant; IP65 rated
No maintenance, calibration, or upkeep needed under normal use
Internal data storage
PRECAUTIONS
(a) Read all instructions before using the instrument; it must be used ONLY as intended and described in this manual
(b) Do not immerse or operate the instrument under water; avoid excessive dust and dirt.
(c)
Do not operate the Ozilla Ozone Gas Detector near chemical vapors or heat sources (like heating fans or dryers); it will register false ozone
readings.
(d) Do not attempt to repair or open the instrument unless you are a qualified repair technician.
(e) IMPORTANT: exposure of the detector to ozone levels in excess of 50.00 PPM may cause sensor damage and void device warranty.
SPECIFICATIONS (F.S. = Full Scale)
Shell material: ABS + PC
Ingress Protection rating: IP65
Detection accuracy: ±3% F.S.
Linerarity error: ≤±1% F.S.
Zero drift: ≤±1% (F.S./year)
Repeatability: ≤±1% F.S.
Reaction time: ≤20 seconds
Recovery time: ≤20 seconds
Pressure range: -30 Kpa ~ 100 Kpa
Dimensions (Length x Width x Height): 180 × 80 × 60 mm
Weight: 500 g

OPERATION

I. Important General Notes-PLEASE READ FIRST!
The Ozilla Ozone Gas Pro detector has a sensitive sensor which is negatively affected by gas levels in excess of 50.00 PPM. Avoid
exposing the detector to gas levels that exceed 50.00 PPM.
Each Ozilla Ozone Gas Detector Pro is precisely calibrated again a standardized ozone gas input. It is not necessary for users to re-
calibrate the detector after purchase unless the detector is used under conditions where gas levels are extremely high (outside the
maximum range of 50.00 PPM) for prolonged periods of time. To avoid damaging the detector, calibration should only be performed
by qualified technicians
To silence an audible alarm, users can press the up or down button.
To save a gas reading in the detector, press the up button for a gas reading in the detector, press the up button for 3-5 seconds. See
Ozilla® Ozone Gas Detector Pro
analog-to-digital (
Explosion-proof level: Exd II CT4
Alarm type: acoustic
Detection method: pump (compatible with small amount of negative pressure)
Unit of detection: parts per million (PPM)
Detection options: real-time or time window
Working temperature: - 40 ~ 60
Work humidity: 0 ~ 95% relative humidity (non-condensing)
Working voltage: 3.7 Volts DC
Data storage: Auto or Manual storage; ~100,000 data group capacity
Charger specifications: INPUT: 100-240V; OUTPUT: 5.0 VDC, 1A.
Battery: 3.7VDC, rechargeable polymer, 4000 mAh
ADC) acquisition chip.
C