Dr. Mach Mach 380 Инструкции по монтажу - Страница 10

Просмотреть онлайн или скачать pdf Инструкции по монтажу для Наружное освещение Dr. Mach Mach 380. Dr. Mach Mach 380 14 страниц. Stand lamp

Dr. Mach Mach 380 Инструкции по монтажу
Mach 380 / Mach M3 Stand model
17,18
19,20
59520001

7. Changing the fuses

Changing the fuses on the transformer
housing
The fuses 17 at the transformer housing pre-
vent the transformer burning through in the
event of a short circuit.
Visible type 5x20/2,5A/250V/T 250 V
Changing the fuses inside the trans-
former housing
The fuse 19 inside the transformer housing
protects the secondary side of the transformer.
Visible type 5x20/10A/250V/T 250 V
• Turn off the lamp.
• Remove the cover of the transformer hous-
ing. For removing the cover loosen the four
plastic quick-lock fasteners with an appro-
priate screw driver.
• Remove the black fuse holder 20 with an
appropriate tool.
• Exchange the fuse.
• Mount the fuse holder 20 under slight pres-
sure.
• Mount the cover of the transformer housing.
Edition 10
Turn off the lamp.
Turn the black fuse holder 18 ¼ of a rota-
tion anticlockwise with a screwdriver.
Change the fuses.
Insert the fuse holder 18 under slight pres-
sure and rotate in a clockwise direction
(bayonet catch).
11.08.2004 / Bak Page 10/14
Dr. Mach
Lamps and Engineering