CONNECTION HINTS:
Water connection 3/8" NPT female. Inlet water pressure
range 5 - 120 psi (0.3 – 8.27 bars).
When reconnecting the water supply to the water valve,
don't overtighten the elbow fitting.
Using Teflon tape on water fittings can help prevent
leaking.
5.6
Drain pumps
Tools needed: T20 Torx & #2 Phillips screwdrivers and pliers.
1. Remove outer door – section 5.1.2.1.
2. Remove toe kick – section 5.1.4.1.
3. Remove base insulation (on models with insulation).
4. Turn off water and disconnect water line (below left).
5. Turn off electricity and disconnect electric supply by
unplugging power cord or disconnecting wire harness /
loosening strain relief (below center & right).
702_58300000130262_ara_en_c
6. Remove the drain pump by rotating it clockwise and pulling
it out (below left).
7. Disconnect wire harness from drain pump (below center).
5.7
Water inlet & condensation tube
The water inlet and condensation tube are easily accessed from
the left side of the dishwasher.
condensation tube connect to the same assembly.
Tools needed: T20 Torx & #2 Phillips screwdrivers and pliers.
1. Remove toe kick – section 5.1.4.1.
2. Disconnect & pull out dishwasher – section 5.1.4.2.
3. Remove lower rack (below left).
4. Unscrew condensation tube cap ccw (counterclockwise)
from inside of tank (below right).
The water inlet hose and
Page 30 of 50