Avoid
Electrical
Shock
Hazard
Do not work
on an energized
circuit.
Doing
so could
result
in serious
injury
or death.
Only
qualified
electricians
should
perform
electrical
work.
Do
not attempt
any work
on the
dishwasher
electric
supply
circuit
until you are certain
the circuit
is de-
energized.
Avoid
Fire Hazard
Make
sure electrical
work
is properly
installed.
Only
qualified
electricians
should
perform
electrical
work.
Electrical
Supply
The customer has the responsibility
of ensuring that the
dishwasher electrical installation
is in compliance
with all
national
and local electrical
codes and ordinances.
The
dishwasher is designed for an electrical supply of 120V, 60
Hz, AC, connected
to a dishwasher-dedicated,
properly
grounded electrical circuit with a fuse or breaker rated for 15
amps. Electrical supply conductors shall be a minimum #14
AWG copper wire rated at 75°C (167°F) or higher.
Electrical
Connection
The dishwasher electrical supply junction box and dedicated
receptacle
must be mounted
in an accessible
cabinet
adjacent to the dishwasher (do not mount the junction box
or receptacle behind the dishwasher). You will need a 41/4''
x 2" (108 x 51ram) opening through the cabinet in order to
pass the junction box through (see Figure 4). If the opening
is made through wood, sand it smooth. If the opening is
made through metal, use the included protective grommet
or other approved method to protect wiring from damage.
Use the four screws included (or appropriate
fastener) in the
parts bag to securely mount the junction box so that it can
be easily accessed (see Figure 4). The electrical supply can
be connected in two ways:
li
Figure 4
7
Avoid Fire Hazard
Make sure there are no loose electrical
connections.
Make sure all electrical connections are properly made.
Grounding
Instructions
This appliance
must be grounded.
In the event
of a
malfunction
or breakdown,
grounding
will reduce the risk
of electric shock by providing a path of least resistance for
electric current. This appliance is equipped with a cord having
an equipment-grounding
conductor and a grounding
plug.
The plug must be plugged
into an appropriate
outlet that
is installed and grounded in accordance with all local codes
and ordinances.
The dishwasher
must
be properly
grounded
before
operating.
This appliance
must be connected
to a
grounded
metal
permanent
wiring
system,
or an
equipment grounding conductor must be run with the circuit
conductors
and connected
to the equipment
grounding
terminal
or lead on the dishwasher. Make sure that the
dishwasher is connected to a suitable ground in compliance
with all local codes or, in the absence of a local code, with
the NATIONAL ELECTRICAL CODE in the United States or
the CANADIAN
ELECTRIC CODE C22.1-1atest edition
in
Canada as well as any provincial/state
or municipal or local
codes that apply.
Dishwasher
Electrical
Rating
Volts
Hertz
Amperes
Watts
120
60
12
1,440
(max)
Method
A-
Three
prong
plug
and
receptacle
Use the included
three-prong
plug and junction
box to
connect to a dedicated
household receptacle.
Make sure
the household
receptacle
meets the electrical
supply
requirements
as well as national and local codes.