STEP 2. The ZRR150 must be in its permanently installed location. Tap the button on the face of the
ZRR150 once when your controller indicates (to include in the network).
STEP 3. You should see an indication on your Controller that the "DEVICE WAS INCLUDED" in the network.
NOTE: If you have trouble adding the ZRR150 to a group it may be that the Home ID and Node ID were not
cleared from it after testing. You must first "RESET UNIT" with your controller to remove it from the network. If
using the ZTH100 select "SETUP" and scroll to "RESET UNIT"
Although adding it to a group includes it in the network, removing it from a group does not remove it from the
network. If removed from a group, it functions only as a repeater.
Receptacle Configuration
The ZRR150 Receptacle controls the ON and OFF of a load connected to the controlled outlet (see diagram on
page one for identification). The other outlet remains powered all the time. A button on the face of the receptacle
is used to configure the module to operate from the wireless controller. With the Wireless Controller, the ZRR150
Receptacle can be turned ON and OFF remotely, and can be included in groups that operate at the same time (a
group can also be a single module), and in scenes that set a lighting mood.
Turn power ON and OFF locally
When the button on the face of the ZRR150 is pressed, the power to the controlled outlet will turn on. When the
button is pressed again, the power will turn off.
Child Protection
The ZRR150 controlled outlet can be set in a child protect mode by the Wireless Controller. When this mode is active,
a user will have to press the button on the face 3 times rapidly to activate the attached load. The module operates
normally when controlled by the Wireless Controller..
Other functions
The button on the face of the ZRR150 Receptacle can be used to carry out inclusion (add to a group), association
(operate simultaneously with other nodes), exclusion (remove from group) or reset (remove from network). This is
described in more detail in the Advanced Wireless Controller instructions on our web site.
The ZRR150 has load sense. If the load that is plugged into the ZRR150's controlled outlet is switched on, the
ZRR150 controlled outlet is turned on. However, this can be disabled. See Configuration section for details.
The ZRR150 has a blue indicator LED. This indicator will turn on when the controlled outlet is on and will turn off when
the controlled outlet is off. However, this behavior can be configured to a "night light" behavior. See Configuration
section below.
ADVANCED OPERATION
Configuration
The ZRR150 supports the Configuration command.
The ZRR150 has some features that can be configured (If your controller supports it).
The ZRR150 can be configured to operate slightly differently than how it works when you first install it. Using the
Configuration command you can configure the following:
You can use a HomePro ZTH100 Wireless Controller to send Configuration commands. (Refer to the Setup Menu,
Configuration section)
Load Sense:
• Parameter No: 29
• Length: 1 Byte
• Valid Values = 0 or 1 (default 1)
Set this parameter to 0 to disable load sense. Set this parameter to 1 to enable load sense.
Nightlight:
•
Configuration Parameter No 3:
•
Length: 1 Byte
•
Valid Values: 0 or 1 (Default: 0)
ZRR150 Instructions, Rel. 1.2