12 Operating Instructions (From Drake
Digital Headend Control Program)
Operating Instructions - From Drake Digital Headend
Control Program
1) Confirm that all connections to the EH24 and its installed
encoder modules have been made as described previously.
Connect a serial cable from the RS232 IN connector on the
EH24 to the serial port on the PC. (This discussion assumes
that the Headend Control Program has already been
installed on the PC as per the instructions supplied with the
software.)
2) Activate the software. You
should see a screen similar to
FIGURE 1 at right.
3) Click on the 'Setup New
Headend' button. This will
bring up the screen shown in
FIGURE 2. Type in the name
of the headend in the
'HeadEnd Name' field and
click on 'OK'. In this case we
have typed in EH24. Then
select the 'PC Baudrate' and
'Using Port'. If you intend to
use a modem instead of a
direct connection, make that
selection using the 'Connect
via:' radio buttons, and type in
the phone number of the
desired modem in the 'Number
to dial' window. Then click
'OK'.
4) You will be presented with
a screen similar to the one
shown on FIGURE 3. Click on
the EH24 tab, and click on the
box representing the EH24 unit ID of the unit you are
programming. In this example we selected Unit ID #1. Then
click on the 'View Edit' button.
Select EH24 Unit ID
View/Edit Button
FIGURE 3
This will bring up the screen shown in FIGURE 4. Click on
the Encoders tab and select the number of the encoder you
choose to program. Set each parameter to the desired
value. Select the number of the next encoder and set each
of its parameters.
Repeat for each
encoder which you
desire to program.
Note that if the value
of the parameter
selected in the left
column differs from
the value of that
parameter in the
selected encoder in
the EH24 shown in
the right column, that
value will appear in
red.
5) Click on the 'QAM
Output' tab and set
each parameter using
the same technique
FIGURE 1
used when setting
encoder parameters.
6) Click on the 'ASI Output' tab and set its values to the
desired values as using the same techniques as above.
7) Click on the 'Set Major/Minor Channel Numbers' button.
You will be presented with a screen shown in FIGURE 5.
8) This screen allows the
user to reasign MPEG
numbers as well as new
major and minor channel
numbers.
FIGURE 2
9) Once the selections
have been made, click on
the 'Download to EH24'
button. This will transfer
all selections on this
screen as well as all
selections made on the
EH24 Tab
previous screens to the
EH24 and its installed
SDE24 modules. Close
this screen by clicking on
the 'X' in the upper right
hand corner of the
screen.
10) You will note that all
of the items in the right
hand columns in the
Encoders, QAM Output
and ASI output screens
are now black and agree with the selections made in the left
hand columns.
11) Additional information on the operation of the Drake
Digital Headend Control Program can be found in the
instructions included on the program CD.