5 Operation, continued
4)
Set up SCTs for download accep
tance: For all SCT860s to be up
graded, press the UP, LEFT, and
ENTER buttons simultaneously for 2
seconds until the displays read:
LOADING PROGRAM. This can apply
to all SCTs connected for remote
control, if desired, however – DO NOT
DOWNLOAD THE FIXED CLOCK
FIRMWARE TO SCTs THAT DO NOT
HAVE THE 1002366 BOARD
INSTALLED. In many installations,
only one SCT will need to be loaded
with the fixed clock firmware.
5)
On the PC, run the SCT860 Control
Program. On the opening screen,
select from the top menu line the
Tools selection. Then select Down
load Firmware... In the new window
that opens there is a selection box
listing all of the files available for
download. For use with the 1002366
board, select Fixed Version 1.4 or
higher hex from the list. Select the
comm Port that you are using on your
PC and then select Start to begin the
download.
6)
When finished, the units will reset
themselves. Press the UP arrow
button on each unit to confirm that
VERSION 1.4F or higher is now
installed.
7)
If it is ever desired to remove the
1002366 board and replace the
original factory installed jumpers, you
must download the Auto Version
firmware to the SCT.
If additional SCTs, not being up
graded with the 1002366 board,
currently have firmware below Version
1.4, you may wish to download the
latest version. In this case you will
need to perform a second download
operation, selecting only these SCTs,
and download the Auto Version 1.4
or higher hex file to those units.
Updates from previous versions
include: revised/limited acquisition
range, correction of a DVB 256QAM
interleave setting, and a few other
minor adjustments (depending on
your current version).
OPERATION
Follow the instructions in the SCT860
instruction manual. Now that the 1002366
board is installed, the FIXED clock option
may be selected and the output BD RATE
(baud rate which is the symbol rate) may
be set. The original AUTO clock mode is
still selectable, if it is desired.
Operation, continued
6