220V Signature/Series E & V by Draper
38 mm Typ
A
Series
E-small case 81 mm
E-large case 114 mm
54 mm
V
NOTE: Viewing surface shown is Series V with tab tensioning.
Series E, without tab tensioning, is also available.
Small Signature Case
Shown with
152
9.5 mm
mm
threaded rod
(provided
by others).
248
cm
Electrical connection
to internal splice box
on left end of case. 22mm
232
knockout for 13 mm
cm
conduit. J-Box cover located
under splice box.
Large Signature Case
Shown with
152
11 mm
mm
threaded
rod (provided
by others).
280
cm
Electrical connection
to internal splice box
on left end of case. 22mm
232
knockout for 13 mm
cm
conduit. J-Box cover located
under splice box.
SCREEN SIZE
Total Drop < 396 cm or viewing width < 366 cm
Total Drop > 396 cm or viewing width > 366 cm
See separate Serial Communication-RS232 Instruction sheet for
enabling RS232 with the MC1.
Program LED
Fuse
RS232 Data FROM Control System
RS232 Data TO Control System
Signal Ground & Manual Switch Common
Manual Switch Down
Manual Switch Up
Eye Port for IR Eye. For RF Receiver
or LED Wall Switch, a Splitter and a
MC1
Power Supply is required. Plug RF
Receiver or LED Wall Switch and
Power Supply into splitter, then run
cable from Splitter to MC1 Eye Port.
Case Dimensions and Methods of Installation
Case length
A
Viewing surface
Varies
Audience
Ceiling grid and tile
(by others)
Audience
Ceiling grid and tile
(by others)
CASE SIZE
Small
Large
MC1
Red-to Screen (directional)
Black-to Screen (directional)
Blue-Common
Brown-Hot to 230V AC
Green/Yellow-Ground
Low Voltage Wiring by others
AC Wiring by electrician
STOP
STOP
230V, 50 Hz.
Control
Switches
24v DC
www.draperinc.com
Tab-Tensioning Cable Adjustment
Draper's Tab-Tensioning System is factory-set, and
under normal circumstances will not require fi eld
adjustment. If, however, you notice wrinkles, waves, or
other indications that the tensioning cables need to be
Ceiling grid
and tile
adjusted, follow the procedure below.
(by others)
➀ Determine which side requires adjustment.
➁ Secure dowel with one hand.
Caution: Do not touch or bend surface.
➂ Using Philips-head screwdriver, depress
spring-loaded adjustment screw (see
Fig. 1) and slowly turn clockwise to tighten
tension, or counterclockwise to loosen tension.
The screw adjusts in ¼ turn increments. Adjust
only one increment (¼ turn).
➃ If problem is not corrected, leave screen in position
for 24 hours to allow surface material to stretch into position.
➄ If problem still is not corrected, repeat steps 2 and 3.
Single Station Control
CE Approved
Terminal strip in
junction box at left
end of screen
Control
switch
Dashed wiring
by electrician
230V,
50 Hz.
Low Voltage & Wireless Control
Terminal strip in
junction box at left
end of screen
All-Pole Disconnect
by Others
(765) 987-7999
Dowel

Wiring Diagrams

Multiple Station Control
Not CE Approved
PE
230V, 50 Hz.
Red-to screen (directional)
Brown-to screen (directional)
White-Common to screen, 110-120V AC
Black-to 110-120V AC
Yellow-to 110-120V AC
Green-Ground
Dashed wiring by electrician
Low voltage wiring by others
Eye Port for IR Eye, RF Receiver or LED
Switch For more than one of these,
a splitter is required.
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Aux Port for connecting additional
LVC-III modules (up to six total-
connect from Aux to Eye).
Page 2 of 2
Tensioning
Cable
Adjustment
Screw
Figure 1
Terminal strip in
junction box at left
end of screen
Cap off with wire
nut & tape
Blue
Red
Black
Blue
Red
Black
Blue
Red
Black
Dashed wiring
by electrician
Terminal strip in
junction box at left
end of screen
All-Pole Disconnect
by Others
STOP
STOP
230V, 50 Hz.
Control
Switches
24v DC