Access/MultiView Electric Pro jec tion Screen & Masking System by Drap er
➀ Read instructions through completely before proceeding.
➁ Follow instructions carefully. Installation contrary to instructions invali-
dates warranty.
➂ Entire bottom of screen case should be unobstructed to permit access
to bottom panel for making electrical connections or servicing.
➃ Screen should be installed level (using a carpenter's level).
➄ Nothing should be fastened to screen dowel, viewing surface or masking.
➅ Operating switches packed separately in screen carton. Do not discard
with packing material.
➆ Screen operates on 110-120v, 60 Hz. current.
NOTE: Screen has been thoroughly inspected and tested at factory and
found to be operating properly prior to shipment.
Hanging Screen
When locating viewing surface and checking clearance for screen operation,
remember surface is centered in the length of the case. Regardless of mount-
ing method used, the following points apply:
➀ Mounting brackets are packed separately in carton. Engage each bracket
with top of housing as shown below and tighten set screws. A bracket
should be within 18" of each end of screen case. Brack ets can be
removed and case mounted with lag screws through top of case (holes
drilled on site).
➁ Screen should be positively and securely supported so that vibration or
even abusive pulling on viewing surface or masking will not weaken
installation.
➂ Installer must insure that fasteners used are of adequate strength and
suitable for the mounting surface chosen. Supporting hardware (chains,
cables, rods, etc.) must be essentially vertical.
➃ Entire bottom of case must be readily accessible after installation is
complete.
➄ Front, back and top of case must be straight—not forced to warp or bow.
➅ If case is painted on location, removal of roller/fabric assembly is recom-
mended prior to painting. If not removed, slot on bottom of case should be
shielded to protect viewing surface from paint splatters or overspray.
➆ Do not seal unit in ceiling until electrical connections have been made
and screen has been operated successfully.
Threaded rod
by others
3
1
/
"
16
7
/
" electrical
8
connection hole
standard on
top of case.
Suitable for use in environmental air space in accordance with Section
300-22(c) of the National Electrical Code, and Sections 2-128, 12-010(3)
and 12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.
Copyright ©2005 Draper Inc. Form AccessMultiView_Inst05
Installation/Operating Instructions
Caution
7
3
/
"
16
5
6
/
"
8
7
7
/
"
16
¾"
1"
8"
Screen and masking each operate on 110-120v, 60 Hz. current.
All connections are made in the junction box located just above the bottom
access panel at left end of screen. Remove the bottom access panel for ac-
cess to the junction box cover (see Bottom Access Panel Removal in struc -
tions below).
Remove four (4) hex head screws that secure the cover to the junction box to
expose two sets of red, black, and white pigtail leads and the green ground
wire per wiring diagram on page 4.
If optional low voltage control or video interface control is specifi ed and factory
installed for either motor, please refer to wiring diagram on page 3.
Screen is shipped with internal wiring complete and control switch(es) fully
boxed. Wire to connect screen to switch(es) and switch(es) to power supply
should be furnished by installer. Connections should be made in accordance
with attached wiring diagram, and wiring should comply with national and
local electrical codes.
All operating switches should be "off" before power is connected.
Bottom Access Panel Installation/Removal
Bottom access panel hooks over the lower inside edge of the screen housing
and then is pivoted downward until the engagement brackets on each end of
the bottom panel click into place with the ball detents on each endcap. Make
sure bottom access panel clicks in place at each end of its length.
With bottom access panel
angled up approx. 20 degrees,
engage hook on the panel
with lip of the housing
Remove bottom access panel by pushing up at each corner of panel
adjacent to slot in bottom of the housing. With bottom access panel angled
up approximately at 20° it can be lifted off of the lip of the housing and then
lowered out of the housing completely.
If you encounter any diffi culties installing or servicing your
Access MultiView screen, call your dealer or Draper, Inc.,
Spiceland, Ind., (765) 987-7999; fax (765) 987-7142; or e-mail
Printed in U.S.A.
Electrical Connections
Using the hook and lip as a pivot,
pull the panel downward until the
engagement brackets click into
place with the ball detent
on each endcap
Engagement bracket
(one on each end of the
bottom access panel)
Bottom flange of Access housing
Bottom access panel pushup
points for panel removal
Access case as seen from below