Draper Access XL Инструкции по установке и эксплуатации - Страница 4
Просмотреть онлайн или скачать pdf Инструкции по установке и эксплуатации для Проекционный экран Draper Access XL. Draper Access XL 5 страниц. Draper access xl electric projection screen
Также для Draper Access XL: Инструкции по установке и эксплуатации (5 страниц), Руководство по эксплуатации (8 страниц)
Access XL Instructions by Draper
9"
7¾"
10
/
"
10"
7
16
8½"
9½"
Typical Installation: Two outermost ceiling
mounting brackets (on the ends) must be
centered over the interior roller brackets
(+/- 4"). Two intermediate brackets should be
spaced evenly from the outermost ceiling
mounting brackets.
Wiring Diagrams—110-120V Motor
Please Note: Do not wire motors in parallel.
Single Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring
by electrician
Control
Single gang box by others
switch
1
7
Min. 4" x 2
/
" x 1
/
" deep
8
8
Blue
Red
Black
Location of key
operated on-off
switch if furnished
To 110-120V Line
Case Dimensions
Evenly Spaced
1"
L
Series V-L=varies
Series E-L=6
/
"
3
8
Ceiling Mounting Bracket Locations and Configurations
Multiple Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Cap off with wire
nut and tape
Red
Blue
Dashed wiring
Black
by electrician
Red
Blue
Black
Red
Blue
Single gang box by others
Black
Min. 4" x 2
1
/
" x 1
8
3 shown. More or less equally
feasible.
Location of key
operated on-off
switch if furnished
To 110-120V Line
www.draperinc.com
Series E Case Length = Fabric width + 12
Series V Case Length = Varies
Centered over roller bracket (+/- 4")
Evenly Spaced
Alternate Installation: Two outermost ceiling mounting
brackets (on the ends) are centered over the interior
roller brackets (+/- 4"), parallel to the case. The two
intermediate brackets should be placed in the typical
perpendicular configuration, and spaced evenly from
Wiring Diagrams—110-120V Motor
with Built-in Low Voltage Controller
Single Low Voltage Control
Internal Screen Wiring
White (Neutral)
Black
Green (Ground)
Dashed wiring
Data Cable
by electrician
Wall Switch,
RF or IR
Receiver,
or integrated
control system
To 110-120V Line
7
/
" deep.
8
*These wiring diagrams are for Access XL screens with motor on audi-
ence left (standard), and fabric unrolling from the back of the roller
(standard).
(765) 987-7999
/
"
3
4
Evenly Spaced
the outermost ceiling mounting brackets.
Multiple Low Voltage Controls
Dashed wiring
by electrician
To 110-120V Line
page 4 of 5
Internal Screen Wiring
White (Neutral)
Black
Green (Ground)
Data
Cables
Wall Switches,
RF or IR
Receivers,
or integrated
control systems