Draper Envoy Инструкции по установке и эксплуатации - Страница 2

Просмотреть онлайн или скачать pdf Инструкции по установке и эксплуатации для Проекционный экран Draper Envoy. Draper Envoy 3 страницы. Electric projection screen
Также для Draper Envoy: Инструкции по установке и эксплуатации (3 страниц), Инструкции по установке и эксплуатации (3 страниц), Инструкции по установке и эксплуатации (2 страниц), Инструкции по установке и эксплуатации (2 страниц), Инструкции по установке и эксплуатации (2 страниц), Инструкции по установке и эксплуатации (3 страниц)

Draper Envoy Инструкции по установке и эксплуатации
220V Envoy by Draper
51
mm
57
mm
16
mm
32
mm
Conduit connection
51mm up on this end
Please Note: Screen limits are factory set for optimum performance of the
screen. A procedure is outlined below for minor tweaks, but any adjustment of
these limits may negatively affect the flatness of the screen surface and could
also void the warranty. Please check with Draper prior to resetting screen limits.
CAUTION: Always be prepared to shut screen off manually when new
adjustment is being tested. Screen may be severely damaged if viewing
surface is allowed to run too far up or too far down.
CAUTION: Be sure all switches are in "off" position before adjusting limit
To Motor
with
Built-In
Low Voltage
Slide
P
O
T
S
Switch
C
o
m
+
m
5V
o
To Motor
DC
n
with
Built-In
Low Voltage
Back View
Please note: When ordering a motor with internal Low Voltage Controller,
if the case ships separate from the "guts," the case includes the 25' cable
POSITION
FUNCTION
and special low voltage switch.
Set LOWER limit
DOWN
Set UPPER limit
UP
Normal Operation
CENTER
Case Dimensions and Wiring Diagrams
Viewing
191
mm
surface
Standard
Construction
Limit Adjustments (Low Voltage Motors with Internal Low Voltage Controller)
switches.
Figure
Please Note: 5V DC must be
connected to be able to set
limits using the wall switch.
FUNCTION
POSITION
Set LOWER limit
DOWN
D
o
U
w
Set UPPER limit
p
UP
n
Normal Operation
CENTER
www.draperinc.com
Fabric Width + 381 mm
closure door
Offset
Construction
3 mm
192
mm
1 Connect the ILT switch to the motor via the terminal blocks, or via the modular port
using four conductor modular cable. When using modular cable, the cable
connectors MUST NOT be crimped in reverse, as with standard telephone cable.
(For a Dry Contacts Wiring Diagram, see page 4.)
2 Set the slide switch to the lower position. Press and hold the DOWN button on the
switch to move the viewing surface to the desired lower limit. If the screen moves in
the opposite direction, release the DOWN button and press and hold down the
STOP button for four seconds. This will reverse the operation of the UP and DOWN
Move slider switch into center position.Wait a couple of seconds.
3
Please Note: If you move the slider switch from down to up in one motion it
Set the slide switch to the higher position. Move the viewing surface to desired
4
upper limit by pressing and holding the UP button on wall switch.
Return the slide switch to the center position to return to normal operation.
5
6 To set the viewing surface to an alternate format position, move the viewing surface
to the desired position and press the STOP button. Press and hold the STOP
button for at least three seconds to record the position.
Please Note: Pressing and releasing the UP button on the switch will move the
screen to its upper limit. Pressing and releasing the DOWN button will move the
While the motor is in motion, pressing the STOP button for less than two
seconds will stop the viewing surface at its present position.
Once the motor is stopped, pressing the STOP button will move the viewing
Pressing and holding the STOP button, when the motor is at rest or in
motion, for at least three seconds will record a new alternate format position.
(765) 987-7999
Ceiling
Ceiling grid and
tile (by others)
Incl. mtg.
198 mm
brackets
192 mm
Support rods
103
by others
mm
Surrounding
ceiling
switches.
sets the two limits in the same position.
screen to its lower limit.
surface to its alternate format position.
Page 2 of 3
51
mm
192
mm
83 mm
Mounting
brackets