Draper Low Voltage, Remote Control, Serial and Network Wiring Guide
See separate Serial
Communication-RS232
Instruction sheet for
enabling RS232 with
the MC1.
Wire to connect power to MC1 should be between 18 AWG and 12 AWG (solid or stranded) 2 conductors with ground. Wire size needs to be suffi cient to
carry the motor load. Red and Black wires are the "open" and "close" leads from the motor. The MC1 comes enclosed in a metal box conforming to the National
Electric Code (NEC) with appropriate spacing between the wires and any exposed parts of the box. Wire to connect system integration products or other
controls using RS232 (two-way serial communication) to MC1 must be 3 conductors with ground. A dry contact wall switch may also be connected to the MC1
using 3-conductor wire.
Wire to connect power to MC1 should be between 18 AWG and 12 AWG (solid or stranded) 2 conductors with ground. Wire size needs to be suffi cient to
carry the motor load. Red and Black wires are the "open" and "close" leads from the motor. The MC1 comes enclosed in a metal box conforming to the National
Electric Code (NEC) with appropriate spacing between the wires and any exposed parts of the box. LS100 for control via Ethernet (network communication) is
connected to MC1 using low voltage modular data or telephone cord (RJ11), which is isolated from the AC power line. This wire is commonly called Silver Satin.
It must be electrically straight (see explanation on page 2). LS100 must be within 1,000 feet of MC1. A dry contact wall switch may also be connected to the
MC1 using 3-conductor wire.
The IPD4 shall be pre-configured with an IP address of 192.168.1.101 and port 4001. To communicate with the LS100, establish a connection to its address
and port, and then transmit data packets containing instructions. Telnet sessions utilize port 6001, via TCP/IP connection.
Follow the standard pin configuration for MC1 wiring (black always on the left, straight through). The ENET port on the IPD4 allows for the network con-
nection to be established. The RJ45 connection (T568A) can be configured as a standard straight through connection (see Fig. 1 below) when connected to
network hub. A cross-over connection (T568B, see Fig. 2 below) is used when connecting directly to a PC without a network connection. A data quality CAT5
cable must be used for the ENET port on the IPD4 and connect to the network.
Pins 4, 5, 7 & 8
are not used
Transmit (3 & 6)
Receive (1 & 2)
Pin #
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Wiring Diagram for Two-Way Serial Communication with RS232
Program LED
Fuse
MC1
Wiring Diagram for One-Way Network Communication via Ethernet with IPD4
White-Common
Red-to Screen (directional)
Brown-to Screen (directional)
Black-Hot to 110-120V AC
Program LED
Green/Yellow-Ground
Low Voltage Wiring by others
Fuse
AC Wiring by electrician
Yellow = Rx (Receive data from control system)
Green = Tx (Transmit data to control system)
Black = Gnd (Signal Ground)
ician
MC1
control system)
trol system)
Red = Unused
For complete installation and configuration instructions, please
see the LS100 User Guide, available at www.draperinc.com
Protocol and Address
Wire Color
Orange/White
Straight-Through
Orange
Wire
Becomes
Green/White
1
1
Blue
2
2
Blue/White
3
3
Green
6
6
Brown/White
Brown
Figure 1
www.draperinc.com
White-Common
Red-to Screen (directional)
Brown-to Screen (directional)
Black-Hot to 110-120V AC
Green/Yellow-Ground
Low Voltage Wiring by others
AC Wiring by electrician
RS232 Data FROM Control System
RS232 Data TO Control System
Signal Ground & Manual Switch Common
Manual Switch Down
Manual Switch Up
Eye Port for IR Eye. For RF Receiver or LED
Wall Switch, a Splitter and a Power Supply
is required. Plug RF Receiver or LED Wall
Switch and Power Supply into splitter, then
run cable from Splitter to MC1 Eye Port.
MJA4
Adapter
Red = Unused
Data
Cable
or
Pins 4, 5, 7 & 8
Transmit (1 & 2)
are not used
Receive (3 & 6)
Receive (3 & 6)
Pins 4, 5, 7 & 8
are not used
Transmit (1 & 2)
(765) 987-7999
RS232
Electrically
Adapter
Straight
Data Cable
192.168.1.101
Subnet = 255.255.255.0
Gateway = 192.168.1.1
RS232
Adapter
Pin #
Wire Color
Pin 1
Orange/White
Crossed-Over
Pin 2
Orange
Wire
Becomes
Pin 3
Green/White
1
3
Pin 4
Blue
2
6
Pin 5
Blue/White
3
1
Pin 6
Green
6
2
Pin 7
Brown/White
Pin 8
Brown
Figure 2
page 5 of 8
LS100
Receive (3 & 6)
Transmit (1 & 2)
Pins 4, 5, 7 & 8
are not used