(7) Fasten the drain hose to the outside wall, etc.
Check the condition of the drain hose and make sure that it is routed correctly.
Good
Prohibited
Drain hose
Saddle
Lifted up
Make sure the drain water is properly drained.
8. TEST RUN
8.1. Test run using PCB (Outdoor unit)
• Refer to the Installation Manual for the outdoor unit if the PCB for the outdoor unit is to
be used for the test run.
8.2. Test run using Remote Controller
• Refer to the Installation Manual for the remote controller to perform the test run using
the wireless remote controller.
• When the air conditioner is being test run, the OPERATION and TIMER indicators
lamps fl ash slowly at the same time.
9. CHECK LIST
Pay special attention to the check items below when installing the indoor unit (s). After
installation is complete, be sure to check the following check items again.
CHECK ITEMS
Has the indoor unit been installed
correctly?
Has there been a check for gas
leaks (refrigerant pipes)?
Has heat insulation work been
completed?
Does water drain easily from the
indoor units?
Is the voltage of the power source
the same as that indicated on the
label on the indoor unit?
Are the wires and pipes all
connected completely?
Is the indoor unit earthed
(grounded)?
Is the connection cable the
specified thickness?
Are the inlets and outlets free of
any obstacles?
Does start and stop air conditioner
operation by remote control unit or
external device?
After installation is completed, has
the proper operation and handling
been explained to the user?
Prohibited
Prohibited
Wave
End in water
CAUTION
If not performed correctly
CHECK BOX
Vibration, noise, indoor unit may
drop
No cooling, No heating
Water leakage
Water leakage
No operation, heat or burn
damage
No operation, heat or burn
damage
Short circuit
No operation, heat or burn
damage
No cooling, No heating
No operation
10. ERROR CODES
If you use a wired type remote controller, error codes will appear on the remote control-
ler display. If you use a wireless remote controller, the lamp on the photodetector unit
will output error codes by way of blinking patterns. See the lamp blinking patterns and
error codes in the table below.
Error display
OPERATION
TIMER lamp
FILTER
lamp (green)
(orange)
lamp (red)
(1)
(2)
(1)
(4)
(1)
(6)
(3)
(1)
(3)
(2)
(4)
(1)
(4)
(2)
(5)
(1)
(5)
(3)
(9)
(15)
Display mode
: 0.5s ON / 0.5s OFF
: 0.1s ON / 0.1s OFF
( ) : Number of fl ashing
Wired Remote Controller Display
Error code
Wired Remote
Controller Error
Error contents
CODE
Remote controller
communication error
Anomalous network
communications
Parallel
communication error
Power frequency error
Model information
error/
EEPROM accession
error
Room temperature
thermistor error
Indoor heat
exchanger
temperature
thermistor error
Indoor fan motor error
Drainage error
Outdoor unit error
En-14