Draper FlexShade NEXD Инструкции Установка и эксплуатация
Bottom-Up FlexShade
Small and Large Hardware

Section 14 - Bead Chain Limits and Safety Device Installation

Attaching Stop Balls
Set upper and lower travel limits by installing stop balls to bead chain
.
(crimp closed using pliers) (Fig. 15)
P-Clip Cord Tension Device
Please Note: Draper Bead Chain Clutch-Operated shades that do not comply with WMCA/ANSI
Standard A100.1-2018 come with a P-Clip cord tension device pre-attached to bead chain
. This device must be attached to wall, jamb, or sill so that bead chain is held taut enough
(Fig. 16)
that children cannot pull it away from wall or fit their head into loop.
Spring-Loaded Cord Tension Device
For Draper
Clutch FlexShades that comply with WMCA/ANSI Standard A100.1-2012, a Spring-
®
Loaded Cord Tension Device comes installed on bead chain
warning label is attached, and approved mechanical fasteners
cord tension device to wall, jamb, or sill.
To install, pull tensioner down and use mounting hardware to keep bead chain taut enough to
move smoothly through device. Without sufficient tension, device will not allow bead chain to
operate shade. This device is designed so that children cannot pull bead chain away from wall
or fit their head into loop
(Safety notes, page 2)
For more information, visit www.draperinc.com/WindowShades/WCMAcompliance.aspx.
Please Note: Overtightening screws will damage the Spring Loaded Tension Device.

Section 15 - Dimensions

C*
B*
Dimension
X***
Y***
***These dimensions are for the Endcap Covers.
Endcap, fascia, or headbox dimensions fall within this dimension.
*These dimensions are different for each shade and are provided by Draper with your order.
Dimension "A" is a vertical cable spacing.
Dimension "B" is the distance from the vertical cable spacing to the vertical edge of the shade.
Dimension "C" is the distance from the Idler-End of the tube to the center of the cable attachment stud.
Dimension "D" is the distance from the Operator-End of the tube the center of the cable attachment stud.
NEXD,
®
(Safety notes, page 2)
. An approved permanent
(Fig. 17)
(wood screws)
.
A*
Large Hardware
4 "
(117mm)
4 "
(117mm)
Shade Width=Cloth Width + 1 "
1. Attach
are included. Install
D*
B*
Small Hardware
3 "
(86mm)
3 "
(98mm)
(41mm)
CHAIN LIMITS
stop balls.
2. Crimp
closed
with
pliers.
Figure 15
CHAIN TENSION DEVICE
Sill
Mount
Tensioner
Figure 17
X
Y
Y
X
page 8 of 8
P-CLIP
P-Clip
Figure 16
Jamb
Mount