4.1 Maintenance Plan

There will be no so much maintenance if use the pump under the normal conditions.
NO.
ITEM
1
Check the oil level
2
Check the oil quality
3
Clean the inlet port
4
Exchange the oil
5
Clean the view window
6
Clean the motor fan

4.2 Important Note

Please always switch the power off before take the pump apart, make sure the pump will not active accidentally,
and observe safety instruction 0.2
Only the related skilled person can doing the related work,inappropriate maintenance will affect the service life
and the performance
If the pump operated under the normal condition,there will be no need for depot repair, you just need to observe
the above maintenance plan.
If the pump have to return to depot, please always contact with us first, there has a file need to be done, and you
have to send the filled file together with the pump, or our maintenance department will return the package back.

4.3 Warranty

TSVP vacuum pump has a one year guarantee from the buying date.
Our company will provide maintenance service free of charge in the period of guarantee provided on the
normal use according to the operating manual.
In case of following failures, repair fare is needed:
1.
Malfunction by nature disasters or artificial factor
2.
Malfunction under special usage
3.
Malfunction of damageable spare parts
4.
Malfunction by non-normal operation or error use which is identified by our technical engineer
TIMELINE
Before start-up, daily maintenance
Before start-up, daily maintenance
Every 6 month under normal condition
After 2000 hrs continuousrunning
Once invisibility
Every 6 month under normal condition
12

4 Maintenance

REMARK
Switch the power off
The oil should be transparent
Observe the local regulation
After the pump is cool down
Observe the local regulation
Switch the power off