Bosch 46 HBN 44 Руководство по установке - Страница 11

Просмотреть онлайн или скачать pdf Руководство по установке для Печь Bosch 46 HBN 44. Bosch 46 HBN 44 28 страниц. Electric built-in single & double oven
Также для Bosch 46 HBN 44: Руководство по эксплуатации и уходу (48 страниц), Руководство по эксплуатации и уходу (48 страниц), Руководство по установке (28 страниц)

Bosch 46 HBN 44 Руководство по установке
CONNECTING TO 208 V CIRCUIT
The
ovens are pre-wired for connection to 240
volt, 60 Hertz supply. If connecting to a 208 volt,
60 Hz. supply a jumper must be used across two
terminals. For the double oven models there are
two jumpers, one for the upper oven and one for
the lower oven. For the single ovens there is one
jumper.
Please refer to figures below for placement of
jumper for 208 volt, 60 hertz connection.
Placing of jumper for single oven
or upper oven of double oven,
for connection to 208 volt, 60 Hz.
Placing of jumper for lower oven
of double oven, for connection to
208 volt, 60 Hz.
To connect to 208 volt circuit:
Remove the access panel(s) located on the
1
back of the oven(s).
2.
Loosen the first and second screws in the ter-
minal block as shown in applicable figure
above.
3.
Place the metal jumper between the first
and second screws and tighten screws to
hold jumper in place.
4.
Replace access panel(s).
9